Fabric OS Administrator’s Guide
163
53-1001763-02
Policy database distribution
7
Matching fabric-wide consistency policies
This section describes the interaction between the databases with active SCC and DCC policies
and combinations of fabric-wide consistency policy settings when fabrics are merged.
For example: Fabric A with SCC:S;DCC (strict SCC and tolerant DCC) joins Fabric B with SCC:S;DCC
(strict SCC and tolerant DCC), the fabrics can merge as long as the SCC policies match, including
the order SCC:S;DCC and if both are set to strict.
Table 38
describes the impact of merging fabrics with the same fabric-wide consistency policy that
have SCC, DCC, or both policies.
Non-matching fabric-wide consistency policies
You may encounter one of the following two scenarios described in
Table 39
and
Table 40
where
you are merging a fabric with a strict policy to a fabric with an absent, tolerant, or non-matching
strict policy and the merge fails and the ports are disabled.
Table 39
on page 164 shows merges that are not supported.
TABLE 38
Merging fabrics with matching fabric-wide consistency policies
Fabric-wide
consistency policy
Fabric A
ACL policies
Fabric B
ACL policies
Merge
results
Database copied
None
None
None
Succeeds
No ACL policies copied.
None
SCC/DCC
Succeeds
No ACL policies copied.
Tolerant
None
None
Succeeds
No ACL policies copied.
None
SCC/DCC
Succeeds
ACL policies are copied from B to A.
SCC/DCC
SCC/DCC
Succeeds
If A and B policies do not match, a
warning displays and policy
commands are disabled
1
.
1.
To resolve the policy conflict, manually distribute the database you want to use to the switch with the mismatched
database. Until the conflict is resolved, commands such as
fddCfg
--
fabwideset
and
secPolicyActivate
are
blocked.
Strict
None
None
Succeeds
No ACL policies copied.
None
SCC/DCC
Succeeds
ACL policies are copied from B to A.
Matching SCC/DCC Matching SCC/DCC Succeeds
No ACL policies copied.
Different SCC/DCC
policies
Different SCC/DCC
policies
Fails
Ports are disabled.
Summary of Contents for 53-1001763-02
Page 1: ...53 1001763 02 13 September 2010 Fabric OS Administrator s Guide Supporting Fabric OS v6 4 0 ...
Page 4: ...iv Fabric OS Administrator s Guide 53 1001763 02 ...
Page 24: ...xxiv Fabric OS Administrator s Guide 53 1001763 02 ...
Page 28: ...xxviii Fabric OS Administrator s Guide 53 1001763 02 ...
Page 32: ...xxxii Fabric OS Administrator s Guide 53 1001763 02 ...
Page 40: ...xl Fabric OS Administrator s Guide 53 1001763 02 ...
Page 42: ...2 Fabric OS Administrator s Guide 53 1001763 02 ...
Page 54: ...14 Fabric OS Administrator s Guide 53 1001763 02 High availability of daemon processes 1 ...
Page 74: ...34 Fabric OS Administrator s Guide 53 1001763 02 Basic connections 2 ...
Page 102: ...62 Fabric OS Administrator s Guide 53 1001763 02 Audit log configuration 3 ...
Page 214: ...174 Fabric OS Administrator s Guide 53 1001763 02 Management interface security 7 ...
Page 228: ...188 Fabric OS Administrator s Guide 53 1001763 02 Brocade configuration form 8 ...
Page 276: ...236 Fabric OS Administrator s Guide 53 1001763 02 Creating a logical fabric using XISLs 10 ...
Page 404: ...364 Fabric OS Administrator s Guide 53 1001763 02 ...
Page 440: ...400 Fabric OS Administrator s Guide 53 1001763 02 Performance data collection 17 ...
Page 480: ...440 Fabric OS Administrator s Guide 53 1001763 02 F_Port masterless trunking 19 ...
Page 494: ...454 Fabric OS Administrator s Guide 53 1001763 02 Buffer credit recovery 20 ...
Page 574: ...534 Fabric OS Administrator s Guide 53 1001763 02 Hexadecimal overview E ...