480
Fabric OS Administrator’s Guide
53-1001763-02
LSAN zone configuration
21
•
fcrPhyDevShow shows the physical devices in the LSAN.
switch:admin>
fcrphydevshow
Device WWN Physical
Exists PID
in Fabric
-----------------------------------------
75 10:00:00:00:c9:2b:c9:0c c70000
2 50:05:07:61:00:5b:62:ed 0100ef
2 50:05:07:61:00:5b:62:ed 0100e8
Total devices displayed: 3
•
fcrProxyDevShow shows the proxy devices in the LSAN.
switch:admin>
fcrproxydevshow
Proxy WWN Proxy Device Physical State
Created PID Exists PID
in Fabric in Fabric
----------------------------------------------------------------------------
75 50:05:07:61:00:5b:62:ed 01f001 2 0100e8 Imported
2 10:00:00:00:c9:2b:c9:0c 02f000 75 c70000 Imported
Total devices displayed: 2
On the FC router, the host and Target A are imported, because both are defined by
lsan_zone_fabric2
and
lsan_zone_fabric75
. However, target B is defined by
lsan_zone_fabric75
and is not imported because
lsan_zone_fabric2
does not allow it.
When a PLOGI, PDISC, or ADISC arrives at the FC router, the SID and DID of the frame are checked.
If they are LSAN-zoned at both SID and DID edge fabrics, the frame is forwarded to the DID. If they
are not zoned, only the PLOGI is dropped; for the remaining frames zoning enforcement takes place
in the edge fabrics.
Setting the maximum LSAN count
You can set the maximum number of LSAN zones, or LSAN count, that can be configured on the
edge fabrics. By default, the maximum LSAN count is set to 3000. You can increase the maximum
LSAN count to 5000 without disabling the switch.
The maximum number of LSAN devices supported is 10000 (this includes both physical and proxy
devices). If you have 3000 LSAN zones but have not exceeded the 10000 device limit, you can
increase the LSAN count to 5000.
All FC routers in the same backbone fabric should have the same maximum LSAN count defined, to
prevent the FC routers from running into indefinite state. Asymmetric LSAN configurations due to
different maximum LSAN counts could lead to different devices being imported on different FC
routers.
1. Enter the fcrlsancount command with no parameters to display the current LSAN limit.
switch:admin>
fcrlsancount
LSAN Zone Limit 3000
2. Enter the fcrlsancount command and specify the new LSAN zone limit.
switch:admin>
fcrlsancount 5000
LSAN Zone Limit 5000
For information on how to display the maximum allowed and currently used LSAN zones and
devices, see
“Resource monitoring”
on page 491.
Summary of Contents for 53-1001763-02
Page 1: ...53 1001763 02 13 September 2010 Fabric OS Administrator s Guide Supporting Fabric OS v6 4 0 ...
Page 4: ...iv Fabric OS Administrator s Guide 53 1001763 02 ...
Page 24: ...xxiv Fabric OS Administrator s Guide 53 1001763 02 ...
Page 28: ...xxviii Fabric OS Administrator s Guide 53 1001763 02 ...
Page 32: ...xxxii Fabric OS Administrator s Guide 53 1001763 02 ...
Page 40: ...xl Fabric OS Administrator s Guide 53 1001763 02 ...
Page 42: ...2 Fabric OS Administrator s Guide 53 1001763 02 ...
Page 54: ...14 Fabric OS Administrator s Guide 53 1001763 02 High availability of daemon processes 1 ...
Page 74: ...34 Fabric OS Administrator s Guide 53 1001763 02 Basic connections 2 ...
Page 102: ...62 Fabric OS Administrator s Guide 53 1001763 02 Audit log configuration 3 ...
Page 214: ...174 Fabric OS Administrator s Guide 53 1001763 02 Management interface security 7 ...
Page 228: ...188 Fabric OS Administrator s Guide 53 1001763 02 Brocade configuration form 8 ...
Page 276: ...236 Fabric OS Administrator s Guide 53 1001763 02 Creating a logical fabric using XISLs 10 ...
Page 404: ...364 Fabric OS Administrator s Guide 53 1001763 02 ...
Page 440: ...400 Fabric OS Administrator s Guide 53 1001763 02 Performance data collection 17 ...
Page 480: ...440 Fabric OS Administrator s Guide 53 1001763 02 F_Port masterless trunking 19 ...
Page 494: ...454 Fabric OS Administrator s Guide 53 1001763 02 Buffer credit recovery 20 ...
Page 574: ...534 Fabric OS Administrator s Guide 53 1001763 02 Hexadecimal overview E ...