Brocade Adapters Troubleshooting Guide
103
53-1001582-01
Adapter driver event messages
A
Authentication unsuccessful for base
port: WWN = [base port WWN or
MAC].
Error
Network and
storage driver
2 (Port)
Failure
Authentication
failure.
Mismatch of
FC-SP
configuration
between switch
and HBA. Also,
check the
authentication
secret setting.
Base port enabled: Hardware
Address = [base port WWN or MAC].
Information
Network and
storage driver
2 (Port)
Enabled
Base port enabled
by user command.
No action
required.
Base port disabled: Hardware
Address = [base port WWN or MAC].
Warning
Network and
storage driver
2 (Port)
Disabled
Base port disabled
by user command.
No action
required.
Base port online: WWN = [Base Port
WWN].
Information
Network and
storage driver
2 (Port)
Online
Base port logged
into fabric.
No action
required.
Base port offline: WWN = [Base Port
WWN].
Warning
Network and
storage driver
2 (Port)
Offline
Base port logged
out of fabric.
No action
required.
Base port (WWN = [base port WWN
or MAC]) lost fabric connectivity.
Error
Network and
storage driver
2 (Port)
Logout
Base port lost
connection with
fabric.
Check switch and
HBA
configuration.
Also, check SFP
and cable
connection
stand-up
adapters.
Heart Beat of IOC [IOC instance
number] is good.
Information
Network and
storage driver
9 (TOC)
Restart
Successful restart
of firmware after a
failure.
No action
required.
Heart Beat of IOC [IOC instance
number] has failed.
Critical
Network and
storage driver
9 (TOC)
Crash
Firmware not
responding.
Collect all error
information and
restart the
firmware. Invoke
bfa_supportsave.
IOC [IOC instance number] is
enabled.
Information
Network and
storage driver
9 (TOC)
Enabled
Adapter firmware
started by user
command.
No action
required.
IOC [IOC instance number] is
disabled.
Warning
Network and
storage driver
9 (TOC)
Disabled
Adapter firmware
stopped by user
command.
No action
required.
New adapter found: SN = [adapter
serial number] base port Hardware
address = [Base port WWN or MAC].
Information
Network and
storage driver
1
(Adapter)
Added
Adapter added to
host.
No action
required.
New SFP found: port [base port
number], Hardware Address = [Base
port WWN or MAC].
Information Network
and
storage driver
(stand-up
adapters only)
2 (Port)
Found
User plugged in an
SFP.
No action
required.
QOS negotiation failed for base port:
WWN = base port WWN or MAC].
Warning
Network and
storage driver
2 (Port)
Failure
QoS negotiation
failed.
Check switch and
HBA
configuration.
TABLE 13
Driver event messages (continued)
Message
Severity
Event Type
Category
Sub
Category
Cause
Action