Brocade Adapters Troubleshooting Guide
109
53-1001582-01
HCM and Installer Message Reference
B
<WWN> is an invalid
WWN or MAC
Occurs when the user adds a invalid WWN (for
example, 00:00:00:00:00:00:00:00) or invalid
MAC address (for example,
00:00:00:00:00:00) in the Detached
WWN/MAC field or Configure Names dialog
box.
Add a valid WWN or MAC address in
the Detached WWN/MAC field or
Configure Names dialog box.
Provide a valid MAC address in the
Detached WWN/MAC field.
No item found
Occurs when the user searches for a
WWN/MAC/name that does not exist using the
search option in the Configure Names dialog
box.
Provide an existing
WWN/MAC/name when searching.
You are about to send
the information to the
agent. Do you want to
proceed?
Occurs when the user performs actions in the
Configure Names dialog box and selects OK or
Apply.
Either select Yes to save all
configurations or No to discard
configurations.
The Name is already in
use. Enter a different
name or clear the
existing name.
Occurs when the user enters duplicate name in
Configure Names or Define Names dialog box.
Provide unique names in these
dialog boxes.
Import of Names is
complete, <Count>
name(s) failed to import
due to invalid
WWN(s)/MAC Address(s)
Occurs when user imports the names file with
invalid WWNs or MAC addresses.
Verify that all the WWNs and MAC
addresses in the names file are
valid.
Data has been entered in
preparation for adding a
name but the name was
not added. Do you want
to add that name before
you exit?
Occurs when user configures names in the
following scenario.
1
Modifies name of any adapter or port
2
Enters WWN and name values in the
Detached WWN/MAC and Name fields
3
Clicks OK.
Verify if the detached WWN/name is
to be added to HCM alias store. If
yes, click Yes to add or No.
Are you sure you wish to
clear the selected
Name(s)?
Occurs when the user deletes the names in
Configure Names using the Remove option.
Select Yes to delete the selected
name and no, to not delete the
selected name.
Found duplicate
name(s). Please resolve.
Occurs when the user selects
User/Administrator will manually fix option in
the Duplicated Names dialog box and does not
provide a unique name.
Provide a unique name in the
Duplicated Names dialog box.
Duplicate names still
exists. Click cancel to
discard duplicated
names. Do you want to
continue?
Occurs when the user selects Cancel button in
Duplicated Names dialog box without making
any changes.
Information message.
IOC for Port 1 will be
disabled to enable
trunking. Do you want to
proceed?
Occurs when the user tries to enable trunking
on the adapter.
Warning that selected port's IOC will
be disabled when you enable
trunking.
Beaconing operation
failed
Occurs in many cases. One case is if the user
performs beaconing operation for a disabled
port, the message “Port is not online
Beaconing operation failed” displays.
Beacon port and beacon link for
valid ports.
TABLE 14
Host Connectivity Manager messages (continued)
Message
Cause
Corrective Action or Notes