Brocade Adapters Troubleshooting Guide
33
53-1001582-01
FCoE and Fibre Channel problems
2
Action: Configure PFC using the appropriate Fabric OS command on the attached switch while
in switch configuration mode.
3. Possible Cause: Zoning is configured incorrectly on FCoE switch.
Action: Verify zoning configuration on the attached switch using the appropriate Fabric OS
command. Refer to the
Fabric OS Command Reference Manual
for more information.
I/Os are not failing over immediately on path failure in MPIO setup
When multipath I/O (MPIO) is enabled and input/output operations are not failing over immediately
when a path failure occurs, refer to the following descriptions of possible causes and
recommended actions to help resolve the problem.
Possible Cause: Improper driver mpiomode setting.
Action: Execute the port --query <port_id> BCU command and ensure fcpim MPIO mode is enabled
(which implies zero Path TOV values) or that fcpim MPIO mode is disabled with the expected “Path
TOV” settings (default is 30 seconds).
Disk I/O requests cause low throughput and high latency on Linux
If a high number of I/O requests is causing low throughput and high latency on Linux systems, refer
to the following descriptions of possible causes and recommended actions to help resolve the
problem.
Possible Cause: The maximum input/output operations per second are too low on Linux hosts.
on page 93 for suggestions to optimize adapter performance in
Linux systems.
Disk I/O requests cause low throughput and high latency on VMware
If a high number of I/O requests is causing low throughput and high latency on VMware systems,
refer to the following descriptions of possible causes and recommended actions to help resolve the
problem.
Possible Cause: The maximum input/output operations per second are too low on VMware hosts.
on page 95 for suggestions to optimize adapter performance in
VMware systems.