58
Fabric Watch Administrator’s Guide
53-1002752-01
Port configuration
7
Port configuration
Use the portThConfig command to configure thresholds for Fabric Watch event monitoring for all
ports of a specified type and to display the configuration and current port status in real time. The
command syntax is detailed in the
Fabric OS Command Reference Guide
.
Before you configure thresholds, you must first identify and select the appropriate class and areas,
which are described in
“Port class areas”
on page 55.
Custom port settings
If you want to customize threshold and action settings (alarms), start with
“Port class guidelines
and default settings”
on page 56. Setting guidelines and default settings for the physical port,
E_Port, FOP_Port, FCU_Port, and VE_Port are different.
NOTE
The FCU_Port, supported on Fabric Watch version 6.4.0 and later, is applicable to copper ports.
The portThConfig command follows a transaction model. When you configure thresholds and
actions with the --set option, the changes are saved persistently to non-volatile storage, but the
changes do not become effective until you execute portThConfig --apply. The --apply option allows
you to toggle between default settings and your own saved custom configuration and to apply
actions and thresholds separately. You may choose to use default thresholds together with a
customized subset of available actions, or you may modify some of the thresholds and use the
default actions. Use the -nosave option to save the configuration non-persistently, and use --cancel
to remove a non-persistent configuration.
Protocol errors (PE)
Monitors the
number of primitive
sequence errors.
Unit: Errors
Time Base: minute
Low: 0
High: 5
Buffer: 0
Below: 0
Above: 0
Informative
Out_of_range
Received packets
(RXP)
Monitors receive
rate, by percentage.
Unit: Percentage (%)
Time Base: minute
Low: 0
High: 100
Buffer: 0
Below: 0
Above: 0
Informative
Informative
Transmitted packets
(TXP)
Monitors
transmission rate, by
percentage.
Unit: Percentage (%)
Time Base: minute
Low: 0
High: 100
Buffer: 0
Below: 0
Above: 0
Informative
Informative
I
Link reset
Monitors the
number of link
resets sent by a
given port (LR-Out)
and received on a
given port (LR-In).
Unit: Errors
Time Base: minute
Low: 0
High: 500
Buffer: 50
Below: 0
Above: 0
Informative
Out_of_range
TABLE 16
Port class default settings (Continued)
Area
Description
Default threshold
settings
Default alarm settings
Threshold state
Summary of Contents for Fabric Watch
Page 10: ...x Fabric Watch Administrator s Guide 53 1002752 01 ...
Page 12: ...xii Fabric Watch Administrator s Guide 53 1002752 01 ...
Page 14: ...xiv Fabric Watch Administrator s Guide 53 1002752 01 ...
Page 38: ...18 Fabric Watch Administrator s Guide 53 1002752 01 Fabric Watch alarm behavior 2 ...
Page 42: ...22 Fabric Watch Administrator s Guide 53 1002752 01 Fabric Watch classes areas and elements 3 ...
Page 56: ...36 Fabric Watch Administrator s Guide 53 1002752 01 Notification configuration 5 ...