System management
• IronView Network manager (INm)
• Web-based Graphical user Interface
• Embedded Web management
• Industry Standard Command line Interface (ClI)
• RmON Hp OpenView for Sun Solaris
• Hp-ux, IBm’s AIx, and Windows NT
• Virtual Cable Tester
• Repeater mIB
Element Security Options
• Authentication, Authorization, and Accounting (AAA)
• RADIuS
• Secure Shell (SSHv2)
• Secure Copy (SCp)
• TACACS/
• username/password (Challenge and Response)
• Bi-level Access mode (Standard and ExEC level)
• protection for Denial of Service attacks, such as TCp SyN or Smurf Attacks
Physical design
• ETSI ETS 300 119-4, Engineering Requirements for Sub-racks in
misc. racks and cabinets
• ANSI/EIA-310-D, Cabinets, Racks, panels, and Associated Equipment
dimensions
FastIron Superx and
FastIron Sx 800
10.4” (H) x 17.5” (W) x 17.3” (D)
26.3 cm (H) x 44.5 cm (W) x 43.8 cm (D)
FastIron Sx 1600
24.5” (H) x 17.5” (W) x 17.3” (D)
62.2 cm (H) x 44.5 cm (W) x 43.8 cm (D)
Weight (Fully Loaded)
FastIron Superx and
FastIron Sx 800
70 lbs (31 kg)
FastIron Sx 1600
196 lbs (88.6 kg)
Environmental
• Operating temperature: 0ºC to 40ºC (32ºF to 104ºF)
• Relative humidity: 5 to 90%, @40ºC (104ºF, non condensing)
• Operating altitude: 6600 ft (2,000 m)
• Storage temperature: -25ºC to 70ºC (-13ºF to 158ºF)
• Storage humidity: 95% maximum relative humidity, non-condensing
• Storage altitude: 15,000 ft (4,500 m) maximum
mTBF
Chassis
• Superx Chassis, Fan Tray, 1 p/S: 269,386 hrs
• Sx 800 Chassis, Fan Tray, 1 p/S: 142,786 hrs
• Sx 800 Chassis, Fan Tray, 2 p/S: 230,584 hrs
• Sx1600 Chassis, Fan Tray, 2 p/S: 99,908 hrs
• Sx1600 Chassis, Fan Tray, 4 p/S: 213,865 hrs
management modules
• Ipv4 management module with no optics:
287,664 hrs
• Ipv4 management module, Zero ports:
534,522 hrs
• Ipv4 management module, 2x10-GbE ports:
269,436 hrs
• Ipv6 management module, 256mB SDRAm,
no optics: 292,557 hrs
• Ipv6 management module, 512mB SDRAm,
no optics: 287,425 hrs
• Ipv6 management module, 2x10GbE,
no optics: 304,109 hrs
Interface modules (Ipv4
and Ipv6 versions)
• 24-port 10/100/1000 Copper module:
352,103 hrs
• 24-port SFp module: 348,204 hrs
• 2-port 10-GbE module: 464,938 hrs
Power Requirements
System power Supply
(Sx-ACpWR, Sx-DCpWR)
• -40 – -60 VDC Consumption (Amps): 36A
• 100 – 120 VAC Consumption (Amps): 14.3A
• 200 – 240 VAC Consumption (Amps): 7.2A
• AC Frequency: 50 – 60Hz
• max BTu: 4874 BTu/Hr
• max Watts (Output): 1200W
• max Watts (Input): 1428W
1250W poE power Supply
• 100 – 120 VAC Consumption (Amps): 14A
• 200 – 240 VAC Consumption (Amps): 7A
• AC Frequency: 50 – 60Hz
• max BTu: 4736 BTu/Hr
• max Watts (Output): 1250W
• max Watts (Input): 1388W
2500W poE power Supply
(Sx-ACpWR-2500-pOE)
• 200 – 240 VAC Consumption (Amps): 14A
• AC Frequency: 50 – 60Hz
• max BTu: 9471 BTu/Hr
• max Watts (Output): 2500W
• max Watts (Input): 2775W
Safety Certifications
• CAN/CSA-C22.2 No. 60950-1-03
• Information Technology Equipment
• Safety—part 1: General Requirement
• ul 60950-1, Information Technology Equipment—Safety—
part 1: General Requirement
• EN 60950-1, Information Technology Equipment—Safety—
part 1: General Requirement
• IEC 60950-1, Information Technology Equipment—Safety—
part 1: General Requirement
• EN 60825-1, Safety of Laser Products. Equipment Classification,
Requirements and user Guide
• EN 60825-2, Safety of laser products, Safety of Optical Fibre
Communications Systems
Environmental Regulatory Compliance
• RoHS Compliant (5 of 6)
• WEEE compliant
Electromagnetic Emission Certifications
• ICES-003, Electromagnetic Emission
• FCC Class A
• EN 55022/CISpR 22 Class A
• VCCI Class A
• EN 61000-3-2, power line Harmonics
• EN 61000-3-3, Voltage Fluctuation and Flicker
• EN 61000-6-3, Electromagnetic Compatibility
• AS/NZS CISpR 22, Electromagnetic Compatibility
Immunity
EN 61000-6-1, Electromagnetic Compatibility, Generic Standard
EN 55024, Immunity Characteristics Supersedes:
• EN 61000-4-2, ESD
• EN 61000-4-3, Radiated, Radio Frequency, Electromagnetic Field
• EN 61000-4-4, Electrical Fast Transient
• EN 61000-4-5, Surge
• EN 61000-4-6, Conducted Disturbances Induced by Radio
• Frequency Fields
• EN 61000-4-8, power Frequency magnetic Field
• EN 61000-4-11, power Frequency magnetic Field
mounting Options
• 19” universal EIA (Telco) Rack or Tabletop