7
Maximum power consumption
lists the maximum power consumption for the modules and other components in the
Brocade chassis.
TABLE 29
Regulatory compliance
Certifications
Emissions
•
Canada Interference Causing Equipment Regulations
•
EN 55022 / CISPR-22 Class A / VCCI Class A
•
FCC Class A
Electromagnetic
•
EN 61000-3-2 Power Line Harmonics
•
EN 61000-4-2 ESD
•
EN 61000-4-3 Radiated Immunity
•
EN 61000-4-4 EFT
•
EN 61000-4-5 Surge
•
EN 61000-4-6 Low Frequency Common Immunity
•
EN 61000-4-11 Voltage Dips and Sags Generic: EN 50082-1
•
ESD: IEC 61000-4-2; 4 kV CD, 8 kV AD
•
Radiated: IEC 61000-4-3; 3 V/m
•
EFT/Burst: IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal line)
•
Conducted: IEC 61000-406; 3 V
Safety Agency
•
CAN/CSA-C22.2 No. 60950-1-03 / UL 60950-1 – 1st Edition, Safety of Information Technology Equipment
•
EN 60825-1 Safety of Laser Products – Part 1: Equipment Classification, Requirements and User’s Guide
•
EN 60825-2 Safety of Laser Products – Part 2: Safety of Optical Fibre Communications Systems
•
EN 60950-1 / IEC 60950-1 – Safety of Information Technology Equipment
TABLE 30
Maximum power consumption
Hardware Component
1
Maximum Power
Consumption
(Watts)
Maximum Number of Components per Chassis
FSX
FSX 800
FSX 1600
FSX Management Module
150
1
N/A
N/A
FSX 800
and
FSX 1600
Management
Module with 2 10-GbE ports
135
N/A
2
2
FSX 800
and
FSX 1600
Management
Module with no ports
65
N/A
2
2
FSX 800
and
FSX 1600
Management
Module with 8 ports
100
N/A
2
2
Switch Fabric module in the
FSX 800
chassis
45
N/A
2
N/A
Switch Fabric module in the
FSX 1600
chassis
90
N/A
N/A
2
2-port 10-GbE interface module, including
fiber optics
90
8
8
16
24-port GbE copper interface module
90
8
8
16
24-port GbE fiber interface module,
including fiber optics
90
8
8
16