Displaying chassis status and temperature readings
4
The following shows example output of the show chassis command on the
FSX 1600
.
FastIron SX 1600 Router#show chassis
Chassis Type: ANR-FastIron SX 1600-PREM (ANR: Acoustic Noise-Reduced)
Power supply 1 not present
Power supply 2 not present
Power supply 3 not present
Power supply 4 (32005100 - AC - Regular) present, status ok
Power supply 5 not present
Power supply 6 not present Power supply 7 not present
Power supply 8 present, status failed, reason NO AC INPUT
Fan 1 ok, speed (auto): 1<->2<->[[3]]<->4<->5
Fan 2 ok, speed (auto): 1<->2<->[[3]]<->4<->5
Fan controlled temperature:
Rule 1/3 (MGMT CARDS THERMAL PLANE): 41.0 deg-C
Rule 2/3 (LINE CARDS THERMAL PLANE): 46.5 deg-C
Rule 3/3 (SWITCH FABRIC CARDS THERMAL PLANE): 40.5 deg-C
Fan speed switching temperature thresholds:
Rule 1/3 (MGMT CARDS THERMAL PLANE):
Speed 1: NM<----->40 deg-C
Speed 2: 35<----->48 deg-C
Speed 3: 44<----->52 deg-C
Speed 4: 48<----->55 deg-C
Speed 5: 52<----->80 deg-C (shutdown)
Rule 2/3 (LINE CARDS THERMAL PLANE)***active***:
Speed 1: NM<----->40 deg-C
Speed 2: 35<----->48 deg-C
Speed 3: 44<----->52 deg-C
Speed 4: 48<----->55 deg-C
Speed 5: 52<----->80 deg-C (shutdown)
Rule 3/3 (SWITCH FABRIC CARDS THERMAL PLANE):
Speed 1: NM<----->30 deg-C
Speed 2: 25<----->40 deg-C
Speed 3: 35<----->55 deg-C
Speed 4: 50<----->65 deg-C
Speed 5: 60<----->90 deg-C (shutdown)
Slot 1 Temperature: empty
Slot 2 Temperature: empty
Slot 3 Temperature: empty
Slot 4 Temperature: empty
Slot 5 Temperature: empty
Slot 6 Temperature: empty
Slot 7 Temperature: empty
Slot 8 Temperature: empty
Slot 9 Temperature: 34.5 deg-C
Slot 10 Temperature: 41.0 deg-C
cont’d on next page...