TABLE 3
FSX 800 and FSX 1600 management module LEDs (continued)
LED
Description and Position
State
Meaning
Blinking
The port is transmitting and
receiving traffic.
Off
No port connection exists.
Sync-Link
Left-most LED above the port
On (Green)
Two management modules are
present.
Blinking
Active and Standby modules are
syncing.
Off
No port connection exists.
SFP+ port LEDs on SX-FI-2XGMR-XL and SX-FI-2XGMR-XL-PREM management modules only
Port 1
Left SFP+
On (Green)
The SFP+ port is linked.
Blinking
The SFP+ port has TX/RX activity.
Off
The SFP+ port is not linked.
Port 2
Right SFP+
On (Green)
The SFP+ port is linked.
Blinking
The SFP+ port has TX/RX activity.
Off
The SFP+ port is not linked.
Console port
The Console port on SX-FI-ZMR-XL and SX-FI-ZMR-XL-PREM6 management modules and the SX-FI-2XGMR-XL and SX-
FI-2XGMR-XL-PREM management modules has an RJ45 connector.
The Console port interfaces with the control plane only and does not interface with the data plane.
Reset button
The SX-FI-ZMR-XL and SX-FI-ZMR-XL-PREM6 management modules and the SX-FI-2XGMR-XL and SX-FI-2XGMR-XL-PREM
management modules do not have a reset button.
Specifying a port address
You can specify a port address for a data port or a management port.
Specifying a management port
The management port number is always 1. This example shows how to specify the management port:
Brocade (config) # interface management 1
Specifying a data port
The port address format is
slot
/
port
.
•
Slot
specifies the interface slot number. Range is from 1 to 8 (FSX 800) or 1 to 16 (FSX 1600).
•
Port
specifies the port number in the slot. Range is from 1 to 48 depending on the interface module.
This example shows how to specify port 2 in slot 1:
Brocade (config) # interface ethernet 1/2
Hardware components
Brocade FastIron SX Series Chassis Hardware Installation Guide
Part Number: 53-1003613-04
23
Summary of Contents for FastIron SX
Page 10: ...Brocade FastIron SX Series Chassis Hardware Installation Guide 10 Part Number 53 1003613 04 ...
Page 12: ...Brocade FastIron SX Series Chassis Hardware Installation Guide 12 Part Number 53 1003613 04 ...
Page 46: ...Brocade FastIron SX Series Chassis Hardware Installation Guide 46 Part Number 53 1003613 04 ...
Page 80: ...Brocade FastIron SX Series Chassis Hardware Installation Guide 80 Part Number 53 1003613 04 ...
Page 118: ...Brocade FastIron SX Series Chassis Hardware Installation Guide 118 Part Number 53 1003613 04 ...
Page 158: ...Brocade FastIron SX Series Chassis Hardware Installation Guide 158 Part Number 53 1003613 04 ...
Page 164: ...Brocade FastIron SX Series Chassis Hardware Installation Guide 164 Part Number 53 1003613 04 ...
Page 172: ...Brocade FastIron SX Series Chassis Hardware Installation Guide 172 Part Number 53 1003613 04 ...