TABLE 5
Interface modules (continued)
Interface Module
Part Number
FSX 800
FSX 1600
24-port 100/1000 Hybrid Fiber
SX-FI624HF
X
X
2-port 10-Gigabit Ethernet LAN
module
SX-FI62XG
X
X
Third Generation Interface Modules
24-port Gigabit Ethernet copper
interface module with PoE+
SX-FI-24GPP
X
X
24-port Gigabit Ethernet fiber
interface module
SX-FI-24HF
X
X
2-port 10-Gigabit Ethernet
interface module
SX-FI-2XG
X
X
8-port 10-Gigabit Ethernet
interface module
SX-FI-8XG
X
X
48-port 10/100/1000 Mbps
RJ45 Ethernet module with PoE+
SX-FI48GPP
X
X
48-port 10/100/1000 Gigabit
Ethernet copper without POE
SX-FI648C
X
X
48-port 10/100/1000 Gigabit
Ethernet copper with POE
SX-FI648PP
X
X
Hot swap support
•
Interface modules are hot swappable, which means you can remove and replace them without powering down the system;
however, you must issue the
disable module
command before you remove the modules from the device.
•
Issuing the
disable module
command before removing the module is not required on the FSX 800 and FSX 1600 device. This
is referred to as "Enhanced Hot Swap".
•
Do not perform both hot swap removal and hot swap insertion of another line module while hot swap of a line module is taking
place. Wait until the current hot swap of the line module is completed. The following message indicates that the hot swap
insertion of a module is completed:
Module 1 is up and running
The following console message indicates that the hot swap removal of a module is completed:
Powering off the module in slot 1
NOTE
It is recommended that modules be disabled through the CLI before removal from the device. If the operator wishes to remove
the module without first disabling the module, the Enhanced Hot Swap capability in software Release 03.2.00 and later
supports this procedure for the FastIron SX 800 and FastIron SX 1600 device. Enhanced Hot Swap (that is, no CLI
disable
)
should be performed during a maintenance window. On rare occasions, an Enhanced Hot Swap may result in a software reload
of the system. The likelihood of this event is very low.
NOTE
It is important to wait a minimum of 10 seconds between the removal and insertion of a line module. Re-insertion of a line
module less than 10 seconds after the removal of a line module may result in the line module not being properly recognized.
Refer to
on page 128 for instructions.
Hardware components
Brocade FastIron SX Series Chassis Hardware Installation Guide
Part Number: 53-1003613-04
25
Summary of Contents for FastIron SX
Page 10: ...Brocade FastIron SX Series Chassis Hardware Installation Guide 10 Part Number 53 1003613 04 ...
Page 12: ...Brocade FastIron SX Series Chassis Hardware Installation Guide 12 Part Number 53 1003613 04 ...
Page 46: ...Brocade FastIron SX Series Chassis Hardware Installation Guide 46 Part Number 53 1003613 04 ...
Page 80: ...Brocade FastIron SX Series Chassis Hardware Installation Guide 80 Part Number 53 1003613 04 ...
Page 118: ...Brocade FastIron SX Series Chassis Hardware Installation Guide 118 Part Number 53 1003613 04 ...
Page 158: ...Brocade FastIron SX Series Chassis Hardware Installation Guide 158 Part Number 53 1003613 04 ...
Page 164: ...Brocade FastIron SX Series Chassis Hardware Installation Guide 164 Part Number 53 1003613 04 ...
Page 172: ...Brocade FastIron SX Series Chassis Hardware Installation Guide 172 Part Number 53 1003613 04 ...