3. To disconnect power cables from HVAC/HVDC power supplies only, use the following steps.
a)
Remove the cable restraint cover, if installed under the power cord connector, by unscrewing the two torx head screws.
1.
Torx head screws
2.
Metal cable restraint cover
CAUTION
When removing the metal cable restraint cover under the high voltage power supply inlet, remove the two Torx
head screws only.
b) Disconnect the power cable from the power supply.
Note that the latch for the power cable connector is positioned under the connector. Press on the latch using a small
screwdriver or other tool to unlatch from the power supply.
Powering down the chassis
Brocade X6-8 Director Hardware Installation Guide
66
53-1004105-07
Summary of Contents for X6-8