TABLE 15
Core routing blade LED descriptions (continued)
LED purpose
Color
Status
Recommended action
completed booting. If the LED
remains amber, consult the supplier
for your Brocade device.
Slow-flashing amber (on 2
seconds, then off 2 seconds)
Blade is not seated correctly or is
faulty.
Pull the blade out and reseat it. If
the LED continues to flash, replace
the blade.
Fast-flashing amber (on 1/2
second, then off 1/2 second)
Environmental range exceeded.
Check for out-of-bounds
environmental condition and correct
it.
QSFP port status LED
No light (LED is off)
No QSFP module, all four QSFP
ports are disabled
No action needed if the QSFP is
not installed or verify that the QSFP
is fully inserted.
Steady amber
QSFP module is in, all four ports
have no signal/no sync.
Ensure that the cable is properly
connected. If the LED remains
amber, consult the supplier for your
Brocade device.
Blinking amber
Port is disabled or faulted, FC link
activity, segmented, loopback
mode, also during transition
between cable plug in and all four
ports online.
Check for console messages or
wait for all four ports to come
online.
Steady green
QSFP module is in and all ports are
online.
No action needed.
Interpreting WWN card LEDs
Refer to the following illustration and table to interpret the LED patterns of installed WWN cards. LEDs for WWN card 1 and WWN card
2 are located on the WWN card (logo) bezel between the power supplies on the nonport side of the device. The LED patterns may
temporarily change during POST and other diagnostic tests.
FIGURE 33
WWN card LEDs on bezel
1.
Power LED for WWN card 1
2.
Status LED for WWN card 1
3.
Power LED for WWN card 2
4.
Status LED for WWN card 2
TABLE 16
WWN card LED descriptions
LED purpose
Color
Status
Recommended action
Power
No light (LED is off)
Card is not receiving power.
Ensure that device power supplies
are firmly seated, power cables are
Interpreting WWN card LEDs
Brocade X6-8 Director Hardware Installation Guide
53-1004105-07
93
Summary of Contents for X6-8
Page 12: ...Brocade X6 8 Director Hardware Installation Guide 12 53 1004105 07...
Page 20: ...Brocade X6 8 Director Hardware Installation Guide 20 53 1004105 07...
Page 28: ...Brocade X6 8 Director Hardware Installation Guide 28 53 1004105 07...
Page 68: ...Brocade X6 8 Director Hardware Installation Guide 68 53 1004105 07...
Page 84: ...Brocade X6 8 Director Hardware Installation Guide 84 53 1004105 07...
Page 130: ...Brocade X6 8 Director Hardware Installation Guide 130 53 1004105 07...
Page 142: ...Brocade X6 8 Director Hardware Installation Guide 142 53 1004105 07...
Page 160: ...Brocade X6 8 Director Hardware Installation Guide 160 53 1004105 07...
Page 184: ...Brocade X6 8 Director Hardware Installation Guide 184 53 1004105 07...
Page 196: ...Brocade X6 8 Director Hardware Installation Guide 196 53 1004105 07...
Page 230: ...Brocade X6 8 Director Hardware Installation Guide 230 53 1004105 07...