18
9. addItIonal functIons and settIng optIons
The "aux" key (9) is used to set the additional functions. Each brief actuation of the key consecu-
tively selects the following operating modes:
•
Set studio/unit address
>
LED "address" blinks
•
Slow charge (option for weak mains)
>
LED „slow“ blinks
•
Buzzer / ready tone
>
LED „buz“ blinks
After the settings have been made, the "aux" key
can be actuated to return to the normal display
mode; this will happen automatically within about
7 seconds.
The respective LED is activated to allow additional
functions to be set. The displays of the two chan-
nels indicate the current settings which can be
changed with the "
q
/
p
" keys (16 and/or 18). When
the power pack is switched off and on again, it will
be in the "normal display" mode – additional func-
tion settings are preserved.
9.1 set studio / unit address
The "address" function allows a studio workstation and an individual unit address to be assigned
to the Senso power pack.
9.1.1 assignment of studio workstation (st):
The "address" LED is activated with the "aux" key (9). The display of channel 1 (15) indicates the
letters "St" followed by the currently selected studio workstation. A brief actuation of the power
selector keys "
q
/
p
" (16) of channel 1 assigns the chosen studio workstation. A longer actuation of
the power selector keys "
q
/
p
" (16) changes the setting in tens intervals. Up to 99 workstations can
be assigned ("01 to "99"). All units that need to be triggered from the same camera must have the
same studio number.
9.1.2 assignment of unit address (un):
The display of channel 2 (17) indicates the currently selected unit address. A brief actuation of the
power selector keys "
q
/
p
" (18) of channel 2 assigns the chosen unit address.
A longer actuation of the power selector keys "
q
/
p
" changes the setting in tens intervals. Up to 99
different unit addresses ("01 to "99") can be assigned to each studio workstation.
9.2 enable/disable slow charging (slo)
The LED “slow” is selected using the „aux“ key (9). The "slow charge" mode can be switched on or
off (on/--) by briefly actuating the power selector keys "
q
/
p
" (18) of channel 2. "slow" for longer
charging times is an option for weak mains and motor generators. When the slow charge mode is
selected, the LED next to "slow" will light up.