When the top is clean, we have to clean the smoke register placed on the bottom of the stove. To do it, it is necessary remove the lower
decorative plate (depending on the stove model instead of this decorative plate it will be the front chamber to gain access to the register)
(
see drawing D22
) and then, do the next operations:
-
Remove the register cover unscrewing the different screws.
See drawing D23
-
Clean the ashes deposited on the register, clean the soot deposited.
-
Clean the extractor forks and case. Remove the extractor if necessary.
See drawing D23
.
-
Replace all the pieces and check the staunchness of the register.
In the ductable models there is another cleaning register:
-
This register is placed on the left side of the stove, over the smoke
extractor (
see drawing D24
). To get access to it you have to remove
the left side chamber of the stove.
Do the next operations:
-
Remove the register cover unscrewing the different screws. See
drawing D24
-
Clean the ashes deposited on the register, clean the soot deposited.
Drawing D25
-
Replace all the pieces and check the staunchness of the register.
8.9
SEASONAL STOPPAGES
If the stove will not be used for a long time it is convenient to keep the fuel tank empty, such as the screw-type conveyor to avoid the fuel
compacting. Clean the stove and the smoke duct, removing the ashes and other residues, close the stove door. It is recommended to clean
the chimney at least once a year. Meanwhile, check the seals because if they are not in good condition (they do not adjust to the door), they
do not guarantee the proper operation of the stove! For this reason, it would be necessary to change them. If there is humidity in the place
where the stove is installed, put absorbent salts inside the equipment. Protect the internal parts with neutral vaseline in order to keep the
appearance overtime.
8.10
MAINTENANCE REVIEW
It is also advisable to check and clean at least once a year, the
existing ashes registers in the bottom and the top part of the stove.
Your stove has a preventive maintenance notice established after
1200 hours of operation, which will remember you the need of
cleaning the registers of your stove. These operations should be done
exclusively by an authorised technician.
This message is not an alarm, but a reminder or warning. Therefore,
it will allow you to use the stove while this message is shown in the
display (
see drawing D26
).
Please, bear in mind that the stove could need to be cleaned before this 1200 hours established by default or even after them. This depends
on the quality of the fuel used, the smoke installation, and the proper regulation of the stove.
In the following table (also pasted on your stove in the fuel tank cover) you can check the frequency of the maintenance tasks and who must
do it.
D22
D23
D24
D25
D26
END HOURS
SERVICE
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
AIR SERIES
EN
Summary of Contents for Air Series
Page 105: ...104 11 3 NINA FT ...
Page 121: ...120 11 11 SARA NC ...
Page 123: ...122 11 12 EVA FT ...
Page 125: ...124 11 13 EVA NC FT ...
Page 127: ...126 11 14 CORAL FT ...