30
CLEANING TASKS
Dail
y
W
eekl
y
Monthl
y
Ann
ual
Tec
hnician
User
Remove the burner from the chamber and clean the holes with the use of the poker provided. Remove the ash with
a vacuum-cleaner.
√
√
Hoover the ashes which are inside the burner place.
√
√
Operate the scrapers doing a movement from down to up several times. (**Only models provided of its)
√
√
Empty the ash pan or vacuum the ash compartment when necessary.
√
√
Vacuum the bottom of the pellet tank when necessary.
√
√
Clean the internal of the combustion chamber descale in the walls with a correct vacuum cleaner.
√
√
Clean the smoke extractor fan, the whole combustion chamber, pellet tank, whole replacement of the seals and
put again silicone where necessary, smoke duct, reservoirs...
√
√
Check all the electronic components (electronic board, display...)
√
√
Check all the electrical components (resistance, smoke extractor fan, circulator pump).
√
√
9
OPERATION OF THE DISPLAY
9.1
GENERAL INFORMATION OF THE DISPLAY
The display shows information about the stove performance.
Once you access to the menu, you will see different screens and
configurations according to the level of access.
Depending on the working mode, the display may have different
meanings depending on the position in the screen.
Drawing D27
shows an example of a stove off.
Drawing D28
shows the layout of the messages during the
programming or configuration of the working parameters.
Particularly:
1.
The screen area saying “VALUE” shows the value that we
introduce.
2.
The screen area saying “MENU LEVEL” shows the current
menu level.
Drawing D29
shows the meaning of the symbols appearing on the left hand
side of the screen. The screen lighting in the section “status” shows the
activation of the corresponding device according to the following list.
9.2
FUNCTIONS OF THE DISPLAY’S BUTTONS
Button
Description
Modality
Performance description
1
Increases
temperature
PROGRAMMING
Modifies/Increases the value of the selected menu.
ON/OFF
Increases the ambient thermostat temperature value.
2
Decreases
Temperature
PROGRAMMING
Modifies/Increases the value of the selected menu.
ON/OFF
Decreases the ambient thermostat temperature value.
3
Menu (Set)
-
Access the menu.
MENU
Access the following level in the submenu.
PROGRAMMING
Confirms the selected value and move to the following option in the menu.
4
ON/OFF
Unblocking
WORKING
It switches on or off the stove pressing 2 seconds.
BLOCKING
Unblocks the boiler and switches it off.
MENU / PROGRAMMING
Goes back to the previous level menu and saves the modified data.
5
Decreases power
ON/OFF
Decreases the output value of the stove.
MENU
Moves to the previous menu option.
PROGRAMMING
Goes back to the previous submenu value.
6
Increases power
ON/OFF
Increases the output value of the stove.
MENU
Moves to the following menu option.
PROGRAMMING
Moves to the following submenu option.
14:24
21 ºC P-2
D27
OFF
VALUE
AMBIENT TEMPERATURE
STATE
DIALOGUE
POWER
D28
VALUE
MENU LEVEL
STATE
DIALOGUE
D29
PROGRAMMING ACTIVATED
RESISTOR
AUGER
SMOKE EXTRACTOR
EXCHANGER
CIRCULATOR PUMP (ONLY HYDRO MODELS)
ALARM
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
AIR SERIES
EN
Summary of Contents for Air Series
Page 105: ...104 11 3 NINA FT ...
Page 121: ...120 11 11 SARA NC ...
Page 123: ...122 11 12 EVA FT ...
Page 125: ...124 11 13 EVA NC FT ...
Page 127: ...126 11 14 CORAL FT ...