Polycold Cryochiller
Appendices
Installation and Operation Manual
Appendix B: Lifting Rings (Optional)
Brooks Automation
214072 Revision B
12-3
Appendix B: Lifting Rings (Optional)
Optional lifting rings may be installed on the top four corners of the Polycold Cryochiller refrigeration
units to aid in lifting and moving.
Load Shift Hazard
When lifting the Polycold Cryochiller using straps and rings, the
straps may shift slightly due to the offset center of gravity and may
cause death or severe injury.
Ensure that the area beneath the hoist is clear of personal and
equipment when lifting the unit.
Heavy Object Hazard
Electrical Equipment Safety guideline IEC61010-1 and UL61010-1
CI.7.5.3 require that the lifting sling have a safety factor (SF) of at
least 4 times (4X) the weight of the load. Other standards have dif-
ferent safety factors.
Use a lifting device and slings rated according to local regulations
but not less than 2132 kg (4700 lb)
Heavy Equipment
This unit can weigh up to 1300lbs (590kg). This unit may fall when
moved improperly which may cause serious injury or death.
To avoid this hazard, follow these precautions:
• Read the user’s manual before moving
• Use all four hoist rings with overhead lift equipment rated for use
with this load with an adequate safety factor.
• Lift with more than 45 degree angle from horizontal