Using the AnyCall Diagnostic Monitor
C-5
Figure C-2 Example Trace
Ch# Time Direct SAPI TEI C/R Type N(s) N(r) P/F Size
--- ----- -------- ---- ---- --- -------- ---- ---- --- ------
00 1B76 Xmit 00 00 0 SABME 1 0003
01 1B76 Rcvd 00 00 0 SABME 1 0003
01 1B76 Xmit 00 00 0 UA 1 0003
00 1B77 Rcvd 00 00 0 UA 1 0003
00 1B7A Xmit 00 00 0 Setup 00 00 0 0027
01 1B7C Rcvd 00 00 0 Setup 00 00 0 0027
01 1B7C Xmit 00 00 1 Prcdng 00 01 0 000E
00 1B7D Rcvd 00 00 1 Prcdng 00 01 0 000E
00 1B7D Xmit 00 00 1 RR 01 0 0004
01 1B7D Xmit 00 00 1 Alrtng 01 01 0 0009
01 1B7E Rcvd 00 00 1 RR 01 0 0004
00 1B7E Rcvd 00 00 1 Alrtng 01 01 0 0009
00 1B7E Xmit 00 00 1 RR 02 0 0004
01 1B7E Xmit 00 00 1 Connct 02 01 0 0009
01 1B7F Rcvd 00 00 1 RR 02 0 0004
00 1B7F Rcvd 00 00 1 Connct 02 01 0 0009
00 1B7F Xmit 00 00 0 ConAck 01 03 0 0009
01 1B81 Rcvd 00 00 0 ConAck 01 03 0 0009
01 1B81 Xmit 00 00 0 RR 02 0 0004
00 1B82 Rcvd 00 00 0 RR 02 0 0004
00 2C13 Xmit 00 00 0 Discct 02 03 0 000D
01 2C15 Rcvd 00 00 0 Discct 02 03 0 000D
01 2C15 Xmit 00 00 0 RR 03 0 0004
00 2C16 Rcvd 00 00 0 RR 03 0 0004
00 2F3D Xmit 00 00 0 Rlease 03 03 0 0010
01 2F3E Rcvd 00 00 0 Rlease 03 03 0 0010
01 2F3E Xmit 00 00 1 RelCom 03 04 0 0009
00 2F40 Rcvd 00 00 1 RelCom 03 04 0 0009
Summary of Contents for IRAS-24A w/ T1-RBS
Page 28: ...2 8 IRAS 24A T1 ISDN Modem Card Installation and Reference Guide...
Page 150: ...B 4 IRAS 24A T1 ISDN Modem Card Installation and Reference Guide...
Page 164: ...C 14 IRAS 24A T1 ISDN Modem Card Installation and Reference Guide...
Page 170: ...D 6 IRAS 24A T1 ISDN Modem Card Installation and Reference Guide...
Page 176: ...E 6 IRAS 24A T1 ISDN Modem Card Installation and Reference Guide...
Page 186: ...Index 8 IRAS 24A T1 ISDN Modem Card Installation and Reference Guide...