7/19
3.3 ErP Directive - Regulations 1253/2014 - 1254/2014
a)
Mark
-
BROOKVENT
b)
Model
-
aircycle ONE 100
aircycle ONE 150
c)
SEC class
-
A
A
c1)
SEC warm climates
kWh/m
2
.a
-15.6
-16.2
c2)
SEC average climates
kWh/m
2
.a
-37.5
-38.2
c3)
SEC cold climates
kWh/m
2
.a
-75.6
-76.4
Energy label
-
Yes
d)
Unit typology
-
Residential - bidirectional
e)
Type of drive
-
Multi-speed drive
f)
Type of Heat Recovery System
-
Heat recovery
g)
Thermal efficiency of heat recovery
%
74
74
h)
Maximum llow rate
m
3
/h
25
60
i)
Electric power input at maximum flow rate
W
2.6
3.8
j)
Sound power level (L
WA
)
dBA
35
38
k)
Reference flow rate
m
3
/h
17
41
l)
Reference pressure difference
Pa
10
10
m)
Specific power input (SPI)
W/m
3
/h
0.071
0.054
n1)
Control factor
-
1
1
n2
)
Control typology
-
Manual control (no DCV)
o1)
Maximum internal leakage rate
%
N/A
o2)
Maximum external leakage rate
%
1
1
p1)
Internal mixing rate
%
N/A
p2)
External mixing rate
%
N/A
q)
Visual filter warning
-
N/A
r)
Instructions to install regulated grilles
-
N/A
s)
Internet address for pre/disassembly instructions
-
t)
Airflow sensitivity to pressure variations
%
N/A
u)
Indoor/outdoor air tightness
m
3
/h
21
60
v1)
AEC - Annual electricity consumption - warm climates
kWh
1
0.7
v2)
AEC - Annual electricity consumption
–
average climates
jährlicher
kWh
1
0.7
v3)
AEC - Annual electricity consumption -
cold climates jährliche
kWh
1
0.7
w1)
AHS - Annual heating saved - warm climates
kWh
18
18.1
w2)
AHS - Annual heating saved - average climates
kWh
39.9
40
w3)
AHS - Annual heating saved - cold climates
kWh
78
78.2