OPTION 2

: If two or more units are not connected under the same main switch, to reset 

the synchronisation, press at the same time the black pin of each unit (fig. 33) for at least 

3 seconds. 
 
If two or more units are controlled by means of the same  controller (Air Controller or 
similar), they always operate in a synchronised way.Wiring diagram as per fig. 18D 

4.2  Jumper positions 

Intergal jumper set in position A (fig. 20A) means “extract

-

only” mode. Intergal jumper set 

in position B (fig. 20B) means “intake

-

only” mode.

 

The jumper position defines both the air

-flow direction when the unit is activated for the 

first time (for the synchronisation) and the air

-flow direction of the free- cooling mode. 

4.3  Disposal and recycling 

Information on disposal of units at the end of life. 
This product complies with EU Directive 2002/96/EC. 
The  symbol  of  the  crossed-out  dustbin  indicates  that  this  product  must  be  collected 
separately from other waste at the end of its life. The user must, therefore, dispose of the 
product in question at suitable electronic and electro-technical waste disposal collection 
centres, or else send the product back to the retailer when purchasing a new, equivalent 
type device. 
Separate  collection  of  decommissioned  equipment  for  recycling,  treatment  and 
environmentally  compatible  disposal  helps  to  prevent  negative  effects  on  the 
environment and on health and promotes the recycling of the materials that make up the 
equipment. 
 

Improper  disposal  of  the  product  by  the  user  may  result  in  administrative 
sanctions as provided by law. 

 

 

Summary of Contents for AF 90-CYC-ONE-100

Page 1: ...o uk Installation maintenance user manual Applicable to the following aircycle ONE models PRODUCT CODE DESCRIPTION AF 90 CYC ONE 100 aircycle ONE 100 AF 90 CYC ONE 150 aircycle ONE 150 single room hea...

Page 2: ...0 Safety 4 2 1 General Safety 4 2 2 Responsibility of the Installer 5 2 3 Responsibility of the Occupant 5 3 0 Specifications Dimensions 6 3 1 Product versions 6 3 2 Detailed Specification 6 3 3 ErP D...

Page 3: ...kling problems associated with condensation dampness such as mould growth It is recommended that two units are installed in pair when one unit is pulling the other is pushing Pair of units can be inst...

Page 4: ...ance please follow all instructions provided If this product has been misused not properly maintained or handled carelessly it may lead to this guarantee being declared void Brookvent does not accept...

Page 5: ...n are detected disconnect the device from the mains supply and contact a quali ed technician immediately Use only original spare parts for repairs The electrical system to which the device is connecte...

Page 6: ...e air intake to ensure good combustion and proper equipment operation Install the product so that the impeller is not accessible from the air outlet side as veri ed by contact with the Test Finger tes...

Page 7: ...ramic core high thermal efficiency External grille in high quality impact and UV resistant ABS colour RAL 9010 Unique design winglet type impeller providing enhanced aerodynamic properties low noise a...

Page 8: ...power input SPI W m3 h 0 071 0 054 n1 Control factor 1 1 n2 Control typology Manual control no DCV o1 Maximum internal leakage rate N A o2 Maximum external leakage rate 1 1 p1 Internal mixing rate N A...

Page 9: ...the integral jumpers as per g 20A 20B The front cover LED indicates when the Free cooling mode is on An automatic Boost mode can be achieved through a dedicated switch or room sensors like humidity se...

Page 10: ...e cooling mode 4 3 Disposal and recycling Information on disposal of units at the end of life This product complies with EU Directive 2002 96 EC The symbol of the crossed out dustbin indicates that th...

Page 11: ...10 19 5 0 Installation and figures...

Page 12: ...11 19...

Page 13: ...12 19...

Page 14: ...13 19...

Page 15: ...14 19...

Page 16: ...15 19...

Page 17: ...16 19...

Page 18: ...17 19...

Page 19: ...18 19 Notes...

Page 20: ...happy to assist you Brookvent Brook House Dunmurry Industrial Estate Dunmurry Belfast Northern Ireland BT17 9HU T 44 0 28 9061 6505 It is important to retain this manual and make a copy available to...

Reviews: