2/21 

 

IMPORTANT 

 

This  appliance  is  not  intended  for  use  by  persons  (including  children)  with  reduced 
physical sensory or mental capabilities, or lack of experience and knowledge, unless they 
have been given supervision or instruction concerning use of the appliance by a person 
responsible for their safety. 

 

1.0  Introduction 

 

 
A continuous running, low energy, ultra-quiet, alternate flow supply and extract fan with 
heat retention for use in habitable areas such as living rooms, bedrooms, dining rooms, 
basements and hallways. 
 
The unit provides ventilation and reduces indoor air pollutants and humidity levels. The 
unit is ideal for tackling problems associated with condensation dampness such as mould 
growth. 
 
It is recommended that two units are installed in pair: when one unit is pulling, the other 
is pushing. 
Pair of units can be installed in the same room or in different rooms (i.e. livingroom and 
bedroom). The unit is suitable for installation on an outside wall. 
 
The unit should operate continuously, and only be stopped for maintenance or service. 
When heat exchange is not useful (for example in mid-seasons when indoor and outdoor 
temperatures are similar), or when heat exchange is not recommended (for example with 

the option “summer free cooling”), it is recommended to set the unit in “extract

-

only” or 

“intake

-

only” mode and NOT to switch it off.

 

 

1.1  Model Variations 

 
PRODUCT CODE

   

DESCRIPTION 

 

AF 90-CYC-ONEP-100 

aircycle ONE+ 100 

AF 90-CYC-ONEP-150

 

aircycle ONE+ 150 

 
 
 
 

Summary of Contents for AF 90-CYC-ONEP-100

Page 1: ...ation maintenance user manual Applicable to the following Aircycle ONE models PRODUCT CODE DESCRIPTION AF 90 CYC ONEP 100 aircycle ONE 100 AF 90 CYC ONEP 150 aircycle ONE 150 single room heat recovery...

Page 2: ...2 0 Safety 3 2 1 Technical specifications 4 2 2 Responsibility of the Installer 5 2 3 Responsibility of the Occupant 5 3 0 Specifications Dimensions 6 3 2 Detailed Specification 6 3 3 ErP Directive R...

Page 3: ...ling problems associated with condensation dampness such as mould growth It is recommended that two units are installed in pair when one unit is pulling the other is pushing Pair of units can be insta...

Page 4: ...fully to ensure safe installation and operation of the unit The device should not be used for applications other than those specified in this manual After removing the product from its packaging verif...

Page 5: ...sure adequate air return discharge into from the room in compliance with existing regulations in order to ensure proper device operation If the environment in which the product is installed also house...

Page 6: ...he unit is double insulated no earth connection is required No need of condensation drainage system IPX4 degree of protection Power supply 220 240V 50Hz 2 2 Responsibility of the Installer Correct Ins...

Page 7: ...unit status Simplified synchronisation of up to 10 units units get automatically synchronised when they are wired to each other Totally recyclable plastic components Double insulated no earth connect...

Page 8: ...nput SPI W m3 h 0 139 0 80 n1 Control factor 0 65 0 65 n2 Control typology Local demand control o1 Maximum internal leakage rate N A o2 Maximum external leakage rate 1 1 p1 Internal mixing rate N A p2...

Page 9: ...ng functionalities can be activated deactivated When a setting is transferred to the unit a short acoustic signal is emitted and a green led flashes In case the remote controller gets lost or the batt...

Page 10: ...9 21...

Page 11: ...uct in question at suitable electronic and electro technical waste disposal collection centres or else send the product back to the retailer when purchasing a new equivalent type device Separate colle...

Page 12: ...11 21 5 0 Installation and figures...

Page 13: ...12 21...

Page 14: ...13 21...

Page 15: ...14 21...

Page 16: ...15 21...

Page 17: ...16 21...

Page 18: ...17 21...

Page 19: ...18 21...

Page 20: ...19 21 Notes...

Page 21: ...20 21 Notes...

Page 22: ...happy to assist you Brookvent Brook House Dunmurry Industrial Estate Dunmurry Belfast Northern Ireland BT17 9HU T 44 0 28 9061 6505 It is important to retain this manual and make a copy available to...

Reviews: