the data plate (voltage and frequency) correspond to those of the electrical 
mains 

 

 the  electrical  power  supply/socket  is  adequate  for  maximum  device 
power. If not, contact a qualified technician.  

 

The device should not be used as an activator for water heaters, stoves, etc., nor 
should  it  discharge  into  hot  air/fume  vent  ducts  deriving  from  any  type  of 
combustion unit. It must expel air outside via its own special duct.  

 

Operating temperature: -20°C up to +50°C.  

 

The device is designed to extract clean air only, i.e. without grease, soot, chemical 
or corrosive agents, or flammable or explosive mixtures.  

 

Do not leave the device exposed to atmospheric agents (rain, sun, snow, etc.).  

 

Do not immerse the device or its parts in water or other liquids.  

 

Turn off the main switch whenever a malfunction is detected or when cleaning.  

 

For installation an omnipolar switch should be incorporated in the fixed wiring, in 
accordance  with  the  wiring  regulations,  to  provide  a  full  disconnection  under 
overvoltage category III conditions (contact opening distance equal to or greater 
than 3mm).  

 

If the supply cord is damaged, it must be replaced by the manufacturer, its service 
agent or similarly qualified persons in order to avoid a hazard.  

 

Do not obstruct the fan or exhaust grille to ensure optimum air passage.  

 

Ensure  adequate  air  return/discharge  into/from  the  room  in  compliance  with 
existing regulations in order to ensure proper device operation.  

 

If the environment in which the product is installed also houses a fuel-operating 

device (water heater, methane stove etc., that is not a “sealed chamber” type

), it is 

essential to ensure adequate air intake, to ensure good combustion and proper 
equipment operation.  

 

contact with the Test Finger (test probe “B” of the norm EN61032) in compliance 

with the current safety regulations. 

2.1  Technical specifications 

 

 

Front cover (A) removable for cleaning without the use of tools. 

 

Inner ventilation unit (B) and wall support base (D) made of high quality, impact 
and UV-resistant ABS, colour RAL 9010. 

 

Integrated multi-colour led (C) to obtain a visual feedback of the unit status. 

 

Smart humidity control. 

 

Integral temperature sensor for the automatic management of the inversion time 
(comfort mode). 

 

Automatic anti-frost protection to prevent frost building up on the heat exchanger. 

 

Wall support base (D) provided with a ma

gnet “coupling/uncoupling” system which 

allows the ventilation unit to be removed from its base during maintenance. 

 

Back-up touch button (E) at the side of the ventilation unit. 

 

Unique  design  winglet-type  impeller,  providing  enhanced  aerodynamic 
properties, low noise and increased efficiency. 

 

Highly efficient reversible EC motor with integral thermal protection, mounted on 
sealed  for  life  high  quality  ball  bearings.  Designed  for  continuous  reversible 
running. 

Summary of Contents for AF 90-CYC-ONEP-100

Page 1: ...ation maintenance user manual Applicable to the following Aircycle ONE models PRODUCT CODE DESCRIPTION AF 90 CYC ONEP 100 aircycle ONE 100 AF 90 CYC ONEP 150 aircycle ONE 150 single room heat recovery...

Page 2: ...2 0 Safety 3 2 1 Technical specifications 4 2 2 Responsibility of the Installer 5 2 3 Responsibility of the Occupant 5 3 0 Specifications Dimensions 6 3 2 Detailed Specification 6 3 3 ErP Directive R...

Page 3: ...ling problems associated with condensation dampness such as mould growth It is recommended that two units are installed in pair when one unit is pulling the other is pushing Pair of units can be insta...

Page 4: ...fully to ensure safe installation and operation of the unit The device should not be used for applications other than those specified in this manual After removing the product from its packaging verif...

Page 5: ...sure adequate air return discharge into from the room in compliance with existing regulations in order to ensure proper device operation If the environment in which the product is installed also house...

Page 6: ...he unit is double insulated no earth connection is required No need of condensation drainage system IPX4 degree of protection Power supply 220 240V 50Hz 2 2 Responsibility of the Installer Correct Ins...

Page 7: ...unit status Simplified synchronisation of up to 10 units units get automatically synchronised when they are wired to each other Totally recyclable plastic components Double insulated no earth connect...

Page 8: ...nput SPI W m3 h 0 139 0 80 n1 Control factor 0 65 0 65 n2 Control typology Local demand control o1 Maximum internal leakage rate N A o2 Maximum external leakage rate 1 1 p1 Internal mixing rate N A p2...

Page 9: ...ng functionalities can be activated deactivated When a setting is transferred to the unit a short acoustic signal is emitted and a green led flashes In case the remote controller gets lost or the batt...

Page 10: ...9 21...

Page 11: ...uct in question at suitable electronic and electro technical waste disposal collection centres or else send the product back to the retailer when purchasing a new equivalent type device Separate colle...

Page 12: ...11 21 5 0 Installation and figures...

Page 13: ...12 21...

Page 14: ...13 21...

Page 15: ...14 21...

Page 16: ...15 21...

Page 17: ...16 21...

Page 18: ...17 21...

Page 19: ...18 21...

Page 20: ...19 21 Notes...

Page 21: ...20 21 Notes...

Page 22: ...happy to assist you Brookvent Brook House Dunmurry Industrial Estate Dunmurry Belfast Northern Ireland BT17 9HU T 44 0 28 9061 6505 It is important to retain this manual and make a copy available to...

Reviews: