6.6 Tempering Summer Bypass
Feature available on selected models only (AS 90-0103-WINS-01).
The Tempering Summer Bypass feature, unique to Brookvent aircycle systems, functions
via thermostatically responsive solenoid which operates on a scale between 20 Degrees
Celsius (No Summer Bypass) and 27 Degrees Celsius (Fully engaged); gradually increasing
the amount of air directed around the Heat Recovery Core as the temperature of the
supply air from outside rises thus comfortably regulating the indoor air temperature
during warmer months.
This feature is factory set, automatic, and requires no maintenance.
6.7 Fan Fault Indication
Feature available on selected models only
(Product code ending in “**”)
Selected models of the aircycle range offer a fan fault indicator on the digital display.
The display will indicate an issue with either fan.
Do not attempt to further diagnose the issue, all investigative and repair works should be
completed by a competent person using original Brookvent parts.