Technical Specification

 

 

 

 
 

3.1 

General Specification

 

 
Dimensions: 

520mm x 500mm x 255mm 

 

Weight:

  

4kg 

 

Materials: 

Main Enclosure: 

 

ABS 

Electronics Enclosure:  

ABS – V0 rated 

Filter:    

 

 

G4 Rated - Polyester Fibres 

 

Electrical: 

230/240V AC 

 

Function: 

Low rate Thermostat controlled, 100% variable 

 

 

Recommended set-up  

(20l/s) active < 23°c > low (5l/s) 

 
Fully complies with Building Regulations for UK & Ireland. 
 

 
3.2 

Performance Characteristics 

 

 

 

L/S 

Fan Speed Setting 

Specific Fan Power (w/l/s) 

21 

100% Variable Speed 

0.17 

29 

100% Variable Speed 

0.16 

37 

100% Variable Speed 

0.17 

45 

100% Variable Speed 

0.18 

53 

100% Variable Speed 

0.22 

61 

100% Variable Speed 

0.24 

Summary of Contents for Airplus

Page 1: ...airplus 1 1E Last updated 26 03 13 Page 1 of 12 Positive Input Ventilation Applicable to airplus 1 1E Installation and User Maual Instructions for the Installer Maintenance Engineer and End User...

Page 2: ...with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible...

Page 3: ...g install If the attic temperature exceeds the pre set temperature on the thermostat the system will drop to a low rate to prevent over heating of the dwelling There is no user interface with the syst...

Page 4: ...measured air flow at the supply valve Compliance to requirements and local additional rules Explanation of the ventilation system to the user Warning for the user to check or replace the air filters o...

Page 5: ...ter Fibres Electrical 230 240V AC Function Low rate Thermostat controlled 100 variable Recommended set up 20l s active 23 c low 5l s Fully complies with Building Regulations for UK Ireland 3 2 Perform...

Page 6: ...ed suspend the unit from screws fitted to a roof joist approximately 1 3rd down from the highest point in the attic space This is to maximise the heat recovery from the attic into the dwelling The ele...

Page 7: ...ere required Fig 2 Fit Blanking strip block 1 or 2 openings Fig 3 Diffuser cover fitted to diffuser body 4 2 Ductwork and Connections Use the supplied 125mm flexible ducting which should be cut to the...

Page 8: ...current IEE wiring regulations A suitably rated mains supply cable must be used A 5A switch or circuit breaker must be used in the power supply circuit It should be in close proximity to the PIV unit...

Page 9: ...unit should automatically reduce down to the low rate recommended temperature setting is 23 c The thermostat should be placed in the attic space near the unit itself to measure the air temperature be...

Page 10: ...airplus 1 1E Last updated 26 03 13 Page 10 of 12 Wiring Schematic...

Page 11: ...12 months IMPORTANT Always isolate the power to the unit before replacing the filter as the fan becomes accessible and may cause injury To remove the filter pull one end over the spigot by stretching...

Page 12: ...airplus 1 1E Last updated 26 03 13 Page 12 of 12 BROOKVENT Brook House Dunmurry Industrial Estate Dunmurry BT17 9HU T 028 90 616 505 F 02890616518 E info brookvent co uk www brookvent co uk...

Reviews: