background image

 

Evolution 5 Multi-fuel Issue 1 21/07/2015 

 

 

 

Introduction

 

 

 

 

 

 

 

 

 

 

 

 

May we take this opportunity to thank you for choosing one of our cast iron, multi-fuel 
stoves. 

 

 

The term multi-fuel refers to the fact that the appliance is capable of burning either wood 
logs or coal (that is suitable for closed appliances). Both of these fuels have very different 
air requirements in order for them to burn correctly, therefore the air controls need to be 
operated differently depending on the fuel being burned (see section “Stove Operation”). 

 

 

See the section “Lighting the Stove” for further details. After reading this document, if there 
is anything you are unsure about, please contact your dealer or our Technical Support 
Department. 

 

These instructions cover the basic principles to ensure the satisfactory installation of the 
stove, although detail may need slight modification to suit particular local site conditions. In 
all cases the installation must comply with current Building Regulations, Local Authority 
Byelaws and other specifications or regulations as they affect the installation of the stove.

 

It should be noted that the Building Regulations requirements may be met by adopting the 
relevant recommendations given in British Standards BS 8303 and BS EN 15287-1 2007 + 
A1 2010 as an alternative means to achieve an equivalent level of performance to that 
obtained following the guidance given in Approved Document J. 

 

Please note that it is a requirement under the Broseley Fires warranty system that 
the installation of the stove is carried out by a Competent Person registered with a 
Government approved Competent Persons Scheme. HETAS Ltd operate such a 
Scheme and a listing of their Registered Competent Persons can be found on their 
website at 

www.hetas.co.uk

 

 Packing List

 

 

 

 

 

 

 

 

 

 

 

 

1x Cast Iron/Steel Stove   

Separate Box Containing: 

Deluxe Models Only:

 

1x Ashpan 

 

 

 

1x Spigot & Fixings  

 

1x Black Glass (Lid) 

1x Rear Firebrick 

 

 

1x Spigot Ring 

1x Baffle 

 

 

 

1x Ash Tool & Glove Set 

2x Baffle Spacers (metal)   

1x Instruction Booklet 

2x Side Firebrick 

 

 

1x Smoke Exempt Screw 

1x Grate & Grate Support 
1x Steel Log Retainer 
 
All parts will be inside the main stove body upon delivery. 

 

 
 
 

Summary of Contents for Evolution 5 Multi-fuel

Page 1: ...015 1 Installation Operating Instructions Covering Models Evolution 5 Multi fuel Multi fuel Stove Standard Deluxe and Log Store Versions Tested to EN 13240 These appliances must be installed and commi...

Page 2: ...bly 10 Assembly for Smoke control area Exemption 12 Operation Controls Layout 13 Recommended Fuels 14 Lighting the Stove 15 Burning Wood Coal 16 Smoke control area Exemption Requirements 17 Warning No...

Page 3: ...Local Authority Byelaws and other specifications or regulations as they affect the installation of the stove It should be noted that the Building Regulations requirements may be met by adopting the r...

Page 4: ...e should be taken to avoid the possibility of personal injury CO Alarms Building regulations require that whenever a new or replacement fixed solid fuel or wood biomass appliance is installed in a dwe...

Page 5: ...d wood logs only Wood Coal Nominal Heat Output 5 kW 5 kW Total Efficiency 80 5 76 3 Mass CO emission 13 O2 0 35 0 03 Mean Flue Gas Temperature 245 C 295 C Flue Gas Mass Flow 4 1 g s 3 9 g s Fuel Consu...

Page 6: ...Evolution 5 Multi fuel Issue 1 21 07 2015 6 Dimensions All dimensions are in millimetres...

Page 7: ...ons Approved Document J Hearths for more specific details Clearances The stove requires the following clearances around it to ensure the heat is released into the room and to allow sufficient combusti...

Page 8: ...the chimney should be above the roof of the building in accordance with the provisions of Building Regulations Approved Document J If installation is into an existing chimney then it must be sound and...

Page 9: ...etc Under UK building regulations any appliance over 5kW MUST have a fixed permanent air vent see building regulations approved document J for further information Air Vent Calculation For new build p...

Page 10: ...Multi fuel Issue 1 21 07 2015 10 Assembly The diagram below shows the stove with all internals taken out To install the internals simply follow the numbered sequence 1 9 and to remove simply reverse t...

Page 11: ...s it is possible to remove the stove from the log store base for transport purposes Please note it is not possible to convert between a log store and standard version These are two separate products a...

Page 12: ...ch generally apply in the smoke control area The Secretary of State for Environment Food and Rural Affairs has powers under the Act to authorise smokeless fuels or exempt appliances for use in smoke c...

Page 13: ...o enter underneath the grate and wood requiring it from above it is critical that you set the control correctly for the type of fuel being used When burning wood air is directed down the inside of the...

Page 14: ...l which are intended for use on open fires Suitable coal needs to be designed for use on closed appliances Open fires send a large amount of heat up the chimney therefore the fuel needs to burn extrem...

Page 15: ...spaper Form a bed on the grate using the newspaper then add a generous amount of dry kindling in a criss cross pattern as shown below The main door may be left open slightly during kindling Stage 2 Ig...

Page 16: ...l fully as this will cause the stove to fill up with smoke If you no longer want to keep the fire going simply allow it burn out Burning Coal With kindling complete you are now ready to add your appro...

Page 17: ...become fully blackened Additionally for medium and low output burning the air control must be maintained at 100 open for the first 5 minutes after refuelling at which time it is possible to adjust to...

Page 18: ...ng must be carried out onto a sufficient quantity of glowing embers and ash that the new fuel charge will ignite in a reasonable period If there are too few embers in the fire bed add suitable kindlin...

Page 19: ...t attempt to relight the fire until the cause of the fume emission has been Identified and corrected If necessary seek expert advice Firebricks Vermiculite is an industry recognised robust fireproof m...

Page 20: ...ing the Stove We recommend only doing this when the stove is cold using a soft brush to clean any of the stove surfaces this is normally sufficient to remove dust ash and debris For stubborn marks you...

Page 21: ...heat being drawn up the chimney to waste Green or wet wood is being burnt The chimney has excessive draw this is unusual Seek installer advice with regard to installing a Flue Draught Stabiliser The...

Page 22: ...___________________________ Address _________________________________________________________________ Telephone Inc area code ____________________________________________________ HETAS Registration Nu...

Page 23: ...OF BASE 23 SIDE OF BASE 24 M4 SLOTTED SET SCREW 25 M8 LARGE PLAIN WASHER 26 M6 WASHER 27 M6 HEX NUT 28 M6 HEX BOLT 29 M5 PAN HEAD SCREW 30 M5 COUNTERSUNK SCREW 31 M4 SPRING WASHER 32 M4 SPRING WASHER...

Page 24: ...REG No COMPANY NAME COMPANY ADDRESS POSTCODE 3RD YEAR SERVICE completion date SERVICE ENGINEER REG No COMPANY NAME COMPANY ADDRESS POSTCODE 4TH YEAR SERVICE completion date SERVICE ENGINEER REG No CO...

Page 25: ...onditioned units Replaced parts or components will become the property of Broseley Fires Should you wish to claim under the warranty please contact the supplier dealer from whom you purchased the appl...