Summary of Contents for THERMO VERONA DSA

Page 1: ...NING BOILER STOVE PLEASE READ THESE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OPERATING OR SERVICING THIS APPLIANCE A Declaration of Completion Certificate must be obtained for the installation and retained by the end user Failure to comply with these requirements may void the warranty Revision TJ09b ...

Page 2: ...ace within the firebox to maximize the heat output of the appliance and to minimize the discharge of particulate emissions to the atmosphere It is important therefore for appliances to be operated in accordance with our instructions in a manner that maintains a high temperature in the firebox with an adequate supply of air to ensure efficient combustion A good indication of efficient combustion is...

Page 3: ...OSAL 10 0 OPERATING IN TRANSITION PERIODS SUMMER 11 0 MAINTENANCE CLEANING THE APPLIANCE 12A RECOMMENDED CLEANING PRODUCTS 12B DAILY CARE 12C CLEANING THE OUTSIDE OF THE APPLIANCE 12D ASH REMOVAL 12E GLASS CLEANING 12F FLUE MAINTENANCE 12G ROPE SEALS 12H AIR CONTROLS 13 0 INSTALLATION OF THE APPLIANCE 13A FLUE REQUIREMENTS 13B LINING THE FLUE 14 SITING THE APPLIANCE 14A HEARTH REQUIREMENTS 15 ADDI...

Page 4: ...tem during the whole year The THERMO VERONA DSA stove is made of cast iron and plates of steel metal sheet The fire chamber is internally lined with cast iron firebricks There is a turning and extractable grate The stove is equipped with a panoramic door with ceramic glass resistant up to 700 ºC this allows a wonderful view of the flame picture whilst also preventing outputs of sparks and smoke Th...

Page 5: ...OLS The stove is fitted with controls that adjust the flow of air into the unit It is very important that these controls are fully understood in order to achieve the best results from your stove When operating the controls ensure that they are used in small increments and not changed by large amounts suddenly Do not use them like an on off switch It is important that the following controls are use...

Page 6: ...n t empty When wanting to control the stove using the thermostatic control the primary and secondary air controls can be shut According to the chosen position of the thermostat dial the damper will react slowly and alter the combustible air entering the unit This is how a fire would naturally respond to changing air supply As it is a high precision device we recommend moving the lever slowly and w...

Page 7: ...e into consideration ease of splitting ease of ignition and burning how much smoke it produces and its coaling qualities Coaling refers to the ability of a species of wood to form a long lasting bed of hot coals when burned Coaling qualities improve with higher density 5C Hot Plate Operation To operate your hot plate on your stove lift the hot plate cover upwards always using the glove supplied un...

Page 8: ...ir controls The thermostat control should be set to number 5 The ignition control should be pushed in This will open the damper to the chimney fully and create the best condition for the lighting of the fire It will take a few minutes for the fire to establish itself When the fire is burning hot add small pieces of hardwood Keep all the draft controls fully open till a bed of hot glowing embers is...

Page 9: ...ers can stay dormant for long periods when buried in ashes These will then flare up again when exposed to oxygen some knowledge of proper ash removal is required for safety Here are the important points Remove ashes to a metal container using a small trowel Never vacuum the ashes unless it is a genuine Ash Vac This is a vacuum you can buy at hearth shops it is specifically designed for ash removal...

Page 10: ...eaners paint solvents biological powders coarse abrasives or salt Never mix different products as they may cause a chemical reaction with each other and cause harm to either you or the appliance 12A RECOMMENDED CLEANING PRODUCTS For the more stubborn stains a mildly abrasive cleaner should be used such as Astonish This is safe to use on enamel surfaces Do not use Astonish on the chrome components ...

Page 11: ...e then you can dip a damp cloth in the ash and use this to scrub the glass clean 12F FLUE MAINTAINENCE If your appliance is installed into an existing chimney you will need to clean the chimney as well as the flue pipe at least twice a year To do this you will need the appropriate sized chimney brush and rods Call a certified chimney sweep National Association of Chimney Sweeps or other qualified ...

Page 12: ...nd sweeping of the flue Flue pipe should be fitted inside the flue pipe collar spigot to prevent creosote and condensates from running down onto the top of the appliance All flue pipe has to be suitable for solid fuel and fitted in accordance with building regulations whilst complying with current legislation and manufacturers instructions If excessive draw is present then a suitable draught stabi...

Page 13: ...BLE MATERIALS The minimum distance from any NON FLAMMABLE object or one that is NOT sensitive to heat stone brick slate etc and from materials with non flammable structure must be 100 mm s to the rear and on both sides PLEASE REFER TO BUILDING REGULATIONS WALLS ADJACENT TO HEARTHS for further information Where the hearth abuts a wall and the appliance is more than 50mm but not more than 300mm away...

Page 14: ...14 16 0 POSITIONING THE SMOKE DEFLECTOR PLATE ...

Page 15: ... Before connecting up the boiler the installer must ensure that they thoroughly flush all of the systems pipes in order to remove any residue which could compromise the correct operation of all system components Pumps valves etc It is also important to verify the chimney has sufficient draught there are no blockages and that no other appliance exhausts are inserted into the flue 20 0 FILLING UP TH...

Page 16: ...e so has additional connections shown in the diagram below These connections currently cannot be used in the UK however you will need to plug connection B as this is an open vessel into the boiler itself Connections C and A should be left open to the environment as they are a separate coil from the internal boiler of the stove ...

Page 17: ... No COMPANY NAME COMPANY ADDRESS POSTCODE 3RD YEAR SERVICE completion date SERVICE ENGINEER REG No COMPANY NAME COMPANY ADDRESS POSTCODE 4TH YEAR SERVICE completion date SERVICE ENGINEER REG No COMPANY NAME COMPANY ADDRESS POSTCODE 5TH YEAR SERVICE completion date SERVICE ENGINEER REG No COMPANY NAME COMPANY ADDRESS POSTCODE 6TH YEAR SERVICE completion date SERVICE ENGINEER REG No COMPANY NAME COM...

Page 18: ...Replaced parts or components will become the property of Broseley Fires Should you wish to claim under the warranty please contact the supplier dealer from whom you purchased the appliance Do not claim directly to Broseley Fires as they are unable to process any direct claim from an end user Product design and any specifications are subject to change without notice This is due to our continuous pr...