Ventilation
Use only in a well ventilated room.
1 The room in which the heater is to be used must be provided with adequate
ventilation at all times to ensure the proper removal of products of combustion
and to reduce the possibility of condensation. The smallest sized room in
which the appliance should be operated is 48m³ for a living room and 24m³ for
other rooms except for basements, bathrooms and bedrooms where the
appliance should not be used. A permanent vent with an effective area of
62cm
2
is required together with a window that can be opened.
Preparing the appliance for use
1
Fitting the Ceramic Coal Matrix
Loosen the slotted headed screw from beneath the glass door. Lift the door
upwards and remove. (The top of the door is located with a hidden screw in a
keyhole and the door may have to be moved around to free it from the front
casting).
Warning:
The Ceramic Coal Matrix is very fragile.
2 Carefully remove the packaging from above the ceramic. The front of
the ceramic coal matrix is lower than the back. Place the ceramic on its
mounting ledges above the burner. Refit the glass door and tighten the
securing screw.