3 - 14
Adjustment
Adjus
tme
nt
Adjus
tme
nt
Feed dog height adjustment (2)
1. Turn the differential dial to [1], and then turn the
feed adjusting dial to [3].
2. Remove the feed spring.
3. Turn the pulley counterclockwise rotation, and
then the needle bar is the highest position.
4. Loosen the screw (set screw, socket (CP) M4x4)
for the upper knife adjusting shaft.
5. Set the gauge at the position of the figure, and
then turn the upper knife adjusting shaft, and
then adjust the differential feed dog to the
position of contacting with the gauge.
6. Fasten the screw (set screw, socket (CP) M4x4)
for the upper knife adjusting shaft.
Feed adjusting dial
Differential dial
Feed spring
Pulley
Set screw, socket (CP)
M4x4
Upper knife
adjusting shaft
Gauge
Needle
plate
Needle
plate
Differential feed dog
1 mm
Upper knife adjusting shaft
Set screw, socket (CP)
M4x4
Upper knife
adjusting shaft
[When did not operate disassembly,
assembly, and exchange]