5-3
Confidential
1.3
Details of Maintenance Mode Functions
1.3.1 Save maintenance information
<Function>
This function is used to save maintenance information to USB flash memory drive.
<Operating Procedure>
(1) Create a folder in the top hierarchy of USB flash memory drive and name it "Brother".
(2) Connect an USB flash memory drive to the machine in the initial state of maintenance
mode.
(3) Press the [to Network Device2] key, and check that all LEDs go out.
(4) Press the [to Network Device2] key. The to Network Device2 LED lights.
(5) Press the
key. The
LED lights and the machine starts writing the maintenance
information as CSV file into the "Brother" folder in the USB flash memory drive. (CSV file
will be saved as <model name>+<serial number (last nine digits)> ex: ADS-
1000WC3G000001.csv)
(6) When the maintenance information writing is completed, the
LED starts flashing, and the
machine returns to the ready state.
(7) Disconnect the USB flash memory drive.
1.3.2 Save Net Config Print as text
<Function>
This function is used to save Net Config Print to USB flash memory drive as a text file.
<Operating Procedure>
(1) Connect an USB flash memory drive to the machine in the initial state of maintenance
mode.
(2) Press the [to Network Device2] key, and check that all LEDs go out.
(3) Press the [to Network Device2] key twice in the initial state of maintenance mode. The to
Network Device1 LED lights.
(4) Press the
key. The
and
LEDs light.
(5) Press the
key again. The machine saves Net Config Print to USB flash memory drive
as a text file, and returns to the initial state of maintenance mode.
Note:
• Do not connect or disconnect the USB flash memory drive during the machine is writing
the maintenance information (
LED is lit).