2-27
Confidential
Faulty registration
Dark or bluish white
Completely blank
Step
Cause
Remedy
1
Document scanning position
actuator caught in sections of the
machine
Reattach the document scanning position
actuator.
<User Check>
- Check that the contrast setting is not too dark.
Step Cause
Remedy
1
Incorrect white level correction data Execute the maintenance mode function
"Acquire white level data and set CIS scan
area".
2
Dirty calibration sheet
Replace the calibration sheet with a new
one.
3
First side or second side CIS unit
failure
Replace the first side or second side CIS
unit.
4
Main PCB failure
Replace the main PCB ASSY.
<User Check>
- Check that the document is not reversed.
- Check that the document is set in the document tray correctly.
Step Cause
Remedy
1
Incorrect white level correction data Execute the maintenance mode function
"Acquire white level data and set CIS scan
area".
2
First side or second side CIS unit
failure
Replace the first side or second side CIS
unit.
3
Main PCB failure
Replace the main PCB ASSY.
Summary of Contents for ADS-2600W
Page 18: ...Confidential CHAPTER 1 SPECIFICATIONS ...
Page 24: ...Confidential CHAPTER 2 TROUBLESHOOTING ...
Page 30: ...2 4 Confidential 2 2 Paper Feeding Fig 2 2 Feed path ...
Page 64: ...Confidential CHAPTER 3 DISASSEMBLY REASSEMBLY ...
Page 68: ...3 2 Confidential 2 PACKING ...
Page 110: ...Confidential CHAPTER 4 ADJUSTING AND UPDATING SETTINGS AS REQUIRED AFTER PARTS REPLACEMENT ...
Page 128: ...Confidential CHAPTER 5 SERVICE FUNCTIONS ...
Page 148: ...Confidential CHAPTER 6 WIRING DIAGRAM ...
Page 150: ...6 1 Confidential 1 WIRING DIAGRAM ...
Page 151: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE ...
Page 152: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE CONTENTS 1 PERIODICAL MAINTENANCE PARTS 7 1 ...
Page 154: ...Confidential APPENDIX 1 SERIAL NUMBERING SYSTEM ...
Page 158: ...Confidential APPENDIX 3 INSTALLING MAINTENANCE DRIVER ...