3-25
Confidential
9.12 Panel PCB ASSY / Key PCB ASSY /
Rubber key / Top cover sensor / Top cover actuator
(1) Disconnect the panel flat cable from the panel PCB ASSY and the key PCB ASSY.
(2) Remove the two taptite cup S M3x6 screws and the two taptite bind B M3x10 screws to
remove the panel PCB shield.
(3) Release the lock of connector on the panel PCB ASSY, and disconnect the LCD relay PCB
flat cable.
(4) Remove the two taptite cup S M3x6 screws, and remove the panel PCB ASSY.
(5) Disconnect the top cover sensor harness from the key PCB ASSY.
(6) Remove the taptite cup S M3x6 screw, and release the three hooks to remove the key PCB
ASSY.
(7) Remove the rubber key from the panel ASSY.
Fig. 3-21
Panel PCB ASSY
Panel flat cable
Panel PCB shield
Taptite cup S M3x6
Panel ASSY
Hooks
Key PCB ASSY
Rubber key
LCD relay PCB
flat cable
Lock
Taptite bind B M3x10
Taptite cup S M3x6
Taptite cup
S M3x6
Top cover sensor harness
Summary of Contents for ADS-2600W
Page 18: ...Confidential CHAPTER 1 SPECIFICATIONS ...
Page 24: ...Confidential CHAPTER 2 TROUBLESHOOTING ...
Page 30: ...2 4 Confidential 2 2 Paper Feeding Fig 2 2 Feed path ...
Page 64: ...Confidential CHAPTER 3 DISASSEMBLY REASSEMBLY ...
Page 68: ...3 2 Confidential 2 PACKING ...
Page 110: ...Confidential CHAPTER 4 ADJUSTING AND UPDATING SETTINGS AS REQUIRED AFTER PARTS REPLACEMENT ...
Page 128: ...Confidential CHAPTER 5 SERVICE FUNCTIONS ...
Page 148: ...Confidential CHAPTER 6 WIRING DIAGRAM ...
Page 150: ...6 1 Confidential 1 WIRING DIAGRAM ...
Page 151: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE ...
Page 152: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE CONTENTS 1 PERIODICAL MAINTENANCE PARTS 7 1 ...
Page 154: ...Confidential APPENDIX 1 SERIAL NUMBERING SYSTEM ...
Page 158: ...Confidential APPENDIX 3 INSTALLING MAINTENANCE DRIVER ...