2-29
Confidential
Expanded image
Step Cause
Remedy
1
The maintenance mode function
"Acquire white level data and set
CIS scan area" are not set.
Execute the maintenance mode function
"Acquire white level data and set CIS scan
area". (Refer to
.)
2
The firmware is outdated
Install the latest version firmware. (Refer to
.)
3
First side or second side CIS unit
failure
Replace the first side or second side CIS
unit.
4
Main PCB failure
Replace the main PCB ASSY.