Chapter 6 Knife replacement
BAS-6150
74
5. Center fixed knife
5-1. How to dismount the fixed knife
1521S
1520S
1.
Turn off the power supply.
2.
Open cloth slide plate
q
.
3.
Loosen setscrew
w
at the rear end.
4.
Unscrew setscrew
e
at near end and
detach needle plate
r
.
5.
Unscrew shoulder screws
t
and detach
fixed knife
y
from needle plate
r
.
* For attachment after replacement, follow
above steps the other way around from 5
to 1.
5-2. Position adjustment of the center knife (upper knife) and fixed knife
1.
Replace the center knife with the center
knife jig A (accessory).
2.
Loosen the screw B and rotate the pulley
to descend the center knife jig A.
3.
Rotate C and slide D. Press the center knife
jig A and the fixed knife together tightly in
the E plane and fasten the screw B, holding
the pressed condition.
q
r
w
e
t
y
r
A
B
E
C
D
1583S
Summary of Contents for BAS-6150
Page 2: ......
Page 11: ...Chapter 1 Machine Preparation ...
Page 29: ...Chapter 2 Sewing flow ...
Page 41: ...Chapter 3 Settings ...
Page 55: ...Chapter 4 Oiling ...
Page 59: ...Chapter 5 Adjustment For raising the head refer to 3 How to raisethehead in Chapter4 Oiling ...
Page 70: ...Chapter 5 Adjustment BAS 6150 68 ...
Page 71: ...Chapter 6 Knife replacement ...
Page 77: ...Chapter 7 Environment setting ...
Page 85: ...Chapter 7 Environment setting BAS 6150 83 Standard stacker 4 steps 0 1 3 4 2 1530S ...
Page 95: ...Chapter 8 Dipswitch ...
Page 98: ...Chapter 8 Dipswitch BAS 6150 96 ...
Page 99: ...Chapter 9 Error code List ...
Page 103: ...Chapter 10 Troubleshooting ...