3

 

Technical Reference

 

 

 

10.

  Remove the four hex screws securing the tension 

base. Remove tension base from the machine by 
disconnecting the harness at the back and the ground 
wire held on by a screw to the tension base mount. 

 

 
 
 
 
 
 
 
 
 
 

11.

  Loosen the top dead center stopper hex screws.

 

12.

  Loosen the needle bar clamp screws.

 

 
 
 
 
 
 
 
 
 
 

13.

  Pull needle bar up slowly at the top. As you are doing 

so, you will need to remove the spring, presser spring 
plate holder, needle bar clamp, top dead center 
stopper and finally the needle bar cushion. Do not 
remove needle bar completely. Pulling the needle bar 
up until the bottom of it just passes the rubber cushion 
will be enough.

 

14.

  Install new rubber cushion.

 

15.

  Slowly lower needle bar down installing the parts 

removed in step 13 in reverse order.

 

16.

  Repeat for all needle bars.

 

17.

  Install the parts listed in steps 7 and 8 for all needles.

 

 
 
 
 
 

 

Remove 

Needle bar clamp 

Top dead center stopper 

Spring 

Presser spring plate holder 

Pull needle bar up here 

Summary of Contents for BE-1204C

Page 1: ... removing the two lower screws and loosening the two upper screws on the BE 1204 or one upper screw on the BE 1206 3 Remove the right end cover by removing the two lower screws and loosening the one upper screw 4 Remove the right end cover by removing the two lower screws and loosening two upper screws Plus removing a screw on the cover behind the head Remove Loosen ...

Page 2: ...ove the four hex screws from the thread take up lever cover and remove the cover on all heads 8 Loosen the needle bar setscrews and remove the needles 9 Now remove the needle bar setscrews all the way and remove the needle bar thread guides and work clamp cushions Note The work clamp cushion has a groove at the top inside diameter that needs to be facing upward during re assembly Remove Loosen Mid...

Page 3: ... need to remove the spring presser spring plate holder needle bar clamp top dead center stopper and finally the needle bar cushion Do not remove needle bar completely Pulling the needle bar up until the bottom of it just passes the rubber cushion will be enough 14 Install new rubber cushion 15 Slowly lower needle bar down installing the parts removed in step 13 in reverse order 16 Repeat for all n...

Page 4: ...nstruction manual for completing adjustment of each needle bar Note You will need to engage each needle bar by pushing down on the needle bar clamp until it locks in to place before performing the adjustment 19 Assembly machine in reverse order Needle bar shown engaged ...

Reviews: