5-66
Confidential
1.3.35 Assurance Mode Switch Setting
(Maintenance mode 88)
< Function >
When the machine does not function normally because the usage environments or operating
conditions are not usual, the assurance mode switches provide workarounds to make the
machine usable by changing the machine settings to untypical ones.
The machine incorporates seven assurance mode switches (AMS01 through AMS07) that are
firmware switches just as the ones described in
The user is allowed to access the assurance mode switches under the guidance of service
personnel (e.g., by telephone).
The details about AMS01 through AMS05 are described on the following pages.
< Operating Procedure >
(1) Press the
8
key twice in the initial stage of the maintenance mode.
The machine displays "AMS00" on the LCD and becomes ready to accept an assurance
mode switch number.
(2) Enter the desired number from the assurance mode switch numbers (01 through 07).
The following appears on the LCD:
Selector 1
Selector 8
AMSXX = 0 0 0 0 0 0 0 0
(3) Use the or key to move the underline cursor to the selector position to be modified.
(4) Enter the desired number (0 or 1) using the
0
and
1
keys.
(5) Press the
SET
key. This operation saves the newly entered selector values onto the
EEPROM and readies the machine for accepting an assurance mode switch number.
(6) Repeat steps (2) through (5) until the modification for the desired assurance mode switches
is completed.
(7) Press the
X
key to return the machine to the initial stage of the maintenance mode.
Notes •
To cancel this operation and return the machine to the initial stage of the maintenance
mode during the above procedure, press the
X
key.
•
If there is a pause of more than one minute after a single-digit number is entered for
double-digit assurance mode switch numbers, the machine will automatically return to
the initial stage of the maintenance mode.
•
Initializing the EEPROM with Maintenance mode 01 or 91 initializes the AMS switch
settings.
Summary of Contents for Business Smart MFC-J4510dw
Page 18: ...xv Confidential ...
Page 19: ...xvi Confidential ...
Page 20: ...xvii Confidential ...
Page 22: ...xix Confidential ...
Page 23: ...xx Confidential ...
Page 24: ...xxi Confidential ...
Page 51: ...Confidential 2 14 Error Code Contents Refer to page FE ROM data acquisition error 2 57 ...
Page 130: ...3 3 Confidential 2 PACKING 3_131_E ...
Page 153: ...3 26 Confidential 3 Set the protective part 3_002_E Protective part ...
Page 265: ...4 11 Confidential ADF Copy Chart A B C ...
Page 292: ...5 13 Confidential Scanning Compensation Data List ...
Page 294: ...5 15 Confidential Test Pattern ...
Page 317: ...5 38 Confidential pfadj1 Pattern ...
Page 318: ...5 39 Confidential pfadj2 Pattern ...
Page 324: ...5 45 Confidential Vertical Lines Check Pattern ...
Page 325: ...5 46 Confidential Software Correction for Inclination Corrugation Ruled Lines Check Pattern ...