1-8
Confidential
■
Error code 56
Fuser cover opened
■
Error code 58
Error code 59
If the same error is detected again 15 minutes later, the message below is indicated.
Fuser unit failure *It occurs with either of 68, 69, 6A, 6B, 6C, 6D, 6E, 6F, 76 and 78.
Cover is Open
Close the Fuser Cover.
User Check
• Check if the Fuser cover is closed correctly.
Step
Cause
Remedy
1
Harness connection failure of back
cover switch ASSY
Check the harness connection of the back
cover switch ASSY and reconnect it.
2
Eject actuator failure
Re-assemble the eject actuator
3
Eject sensor PCB ASSY failure
Replace the eject sensor PCB ASSY.
4
Main PCB failure
Replace the main PCB ASSY.
Fuser Error
Turn the power off, then on again. Leave the machine for 15 min.
Self-Diagnostic
Will Automatically Restart within 15 minutes.
Print Unable 6A
See Troubleshooting and routine maintenance chapter in User’s Guide.
Step
Cause
Remedy
1
Harness connection failure
between fuser unit and eject
sensor PCB
Check the harness connection between the
fuser unit and eject sensor PCB, and
reconnect it.
2
Fuser unit failure
Replace the fuser unit.
3
LVPS PCB failure
Replace the LVPS PCB unit.
4
Eject sensor PCB ASSY failure
Replace the eject sensor PCB ASSY.
5
Main PCB failure
Replace the main PCB ASSY.
Summary of Contents for DCP-7030
Page 201: ...5 5 Confidential Print sample Fig 5 1 ...
Page 226: ...5 30 Confidential Location of fans Fig 5 13 Fan motor 60 unit Right side ...
Page 234: ...6 2 Confidential LVPS PCB Circuit Diagram 100V ...
Page 235: ...6 3 Confidential LVPS PCB Circuit Diagram 200V ...
Page 239: ...6 7 Confidential Wiring Diagram ...