1-32
Confidential
■
Poor fixing
■
Completely blank
User Check
• Replace the drum unit with a new one.
• Replace the toner cartridge with a new one.
Step
Cause
Check
Result
Remedy
1
Fuser unit
pressure is high
Is the problem solved
after replacing the
position of the pressure
roller?
Yes
Replace the position of the
pressure roller.
(
Refer to Fig. 1-4.
)
2
Fuser unit failure
Is the problem solved
after replacing the fuser
unit?
Yes
Replace the fuser unit.
3
LVPS PCB failure Is the problem solved
after replacing the LVPS
PCB unit?
Yes
Replace the LVPS PCB
unit.
4
HVPS PCB
failure
Is the problem solved
after replacing the
HVPS PCB ASSY?
Yes
Replace the HVPS PCB
ASSY.
5
Main PCB failure
Is the problem solved
after replacing the main
PCB ASSY?
Yes
Replace the main PCB
ASSY.
User Check
• Replace the drum unit with a new one.
• Replace the toner cartridge with a new one.
Step
Cause
Check
Result
Remedy
1
Developing bias
voltage
conduction
failure
Are the electrodes on
the drum unit and
machine body dirty?
Yes
Clean both electrodes.
(
)
2
Scanner harness
of the laser unit
connection
failure
Is the scanner harness
of the laser unit
connected securely?
No
Reconnect the scanner
harness of the laser unit.
3
Laser unit failure
Is the problem solved
after replacing the laser
unit?
Yes
Replace the laser unit.
4
HVPS PCB
failure
Is the problem solved
after replacing the
HVPS PCB ASSY?
Yes
Replace the HVPS PCB
ASSY.
5
Main PCB failure
Is the problem solved
after replacing the main
PCB ASSY?
Yes
Replace the main PCB
ASSY.
Summary of Contents for DCP-7030
Page 201: ...5 5 Confidential Print sample Fig 5 1 ...
Page 226: ...5 30 Confidential Location of fans Fig 5 13 Fan motor 60 unit Right side ...
Page 234: ...6 2 Confidential LVPS PCB Circuit Diagram 100V ...
Page 235: ...6 3 Confidential LVPS PCB Circuit Diagram 200V ...
Page 239: ...6 7 Confidential Wiring Diagram ...