3-52
Confidential
8.12.2 CORD HOOK
(1) Remove the two Taptite cup B M3x8 screws, and then remove the two cord hooks from
the Document scanner unit.
Fig. 3-47
8.12.3 PANEL UNIT
(1) Remove the four Taptite cup B M3x10 screws.
(2) Release the Hook to remove the Panel unit from the Document scanner unit.
(3) Disconnect the connector from the Panel PCB ASSY.
Fig. 3-48
Document scanner unit
Cord hook
Cord hook
Taptite cup B M3x8
Document scanner unit
Connector
Panel unit
Hook
Hook
Taptite cup B M3x10
Taptite cup B
M3x10
2
3
<Bottom side>