App. 1-21
Confidential
<WSW16>
Note:
Selector 7 is applicable to models equipped with ADF units.
• Selector 2: ITU-T (CCITT) superfine recommendation
If this selector is set to "1," the machine communicates in ITU-T (CCITT) recommended
superfine mode (15.4 lines/mm). If it is set to "0," it communicates in native superfine
mode.
• Selector 7: Max. document length limitation
This selector is used to select the maximum length of a document to be sent.
• Selector 8: Stop/Exit button pressed during reception
If this selector is set to "1," pressing the
Stop/Exit
button can stop the current receiving
operation. The received data will be lost.
Selector No.
Function
Setting and Specifications
1
Not used.
2
ITU-T (CCITT) superfine
recommendation
0: OFF
1: ON
3
I
6
Not used.
7
Max. document length limitation
0: 400 cm
1: 90 cm
8
Stop/Exit
button pressed during
reception
0: Not functional 1: Functional