App. 1-35
Confidential
<WSW30>
Note:
Selectors 1 through 3 are applicable to models equipped with internal TADs.
• Selectors 1 through 3:Dial tone/busy tone detection level during recording of ICM
(Not used.)
If the machine (called station) detects dial tone (400 Hz continuously) or busy tone (400 Hz
intermittently) exceeding the detection level specified by these selectors for the period
specified by selectors 1 through 4 on WSW35, then it interprets the calling station as being
disconnected. The machine stops TAD recording and disconnects the line.
• Selector 8: Density adjustment of the copy for text mode
When copy the thin document, thicken the contrast and print it.
Selector No.
Function
Setting and Specifications
1
I
3
Dial tone/busy tone detection
level during recording of ICM
(Not used.)
No. 1 2 3
0 0 0: -38.0 dBm
(A)
0 0 1: -39.5 dBm
(B)
0 1 0: -41.0 dBm
(C)
0 1 1: -42.5 dBm
(D)
1 0 0: -44.0 dBm
(E)
1 0 1: -45.5 dBm
(F)
1 1 0: -47.0 dBm
(G)
1 1 1: -48.5 dBm
(H)
4
Not used.
5
Drum cleaning alarm
0: ON
1: OFF
6
Not used.
7
Scanning magnification
adjusting function (Not used.)
0: Enable
1: Disable
8
Density adjustment of the copy
for text mode
0: Normal
1: Thickening