3-8
Confidential
2.2 Error Messages
The error messages displayed on the LCD of the product and their description and measure
are shown in the table below.
* (X) at the end of the message shows the color of the toner cartridge or drum unit.
(X) must be either K (Black), Y (Yellow), M (Magenta) or C (Cyan).
Error message
Description/Measure
Refer to:
Access Error
(USB direct interface
model only)
The USB device was removed while data was
processing. Press
Job Cancel
button. Reinsert the
USB device and try to print with Direct Print or PictBridge.
Belt End Soon
The belt unit is near the end of its life. Buy a new belt
unit before you get a “Replace Belt” message.
Calibrate
Scroll message:
Calibration failed.
See
Troubleshooting
chapter in User's
guide.
- Turn off the machine. Wait a few seconds and turn it
on again.
- Put in a new drum unit.
- Put in a new belt unit.
- Put in a new waste toner box.
Cartridge Error
Take out the drum unit and toner cartridge assembly for
the toner color that is indicated on the LCD. Remove the
toner cartridge from the drum unit and install a new toner
cartridge in the drum unit. Put the drum unit and toner
cartridge assembly back into the machine again.
Cooling Down Wait
for a while
The temperature of the drum unit or toner cartridge is too
hot.
Comm. Error
Poor telephone line quality caused a communication error.
Connection Fail
You tried to poll a fax machine that is not in polled waiting
mode.
Cover is Open
Close the cover that is indicated on the LCD.
Disconnected
The other person or other person’s fax machine stopped
the call.
Document Jam
The document was not inserted, or fed properly.
DR Mode is Use
The machine is set to Distinctive Ring mode.
Drum End Soon
(X)
*
or
Drums End Soon
The drum unit is near the end of its life. Buy a new toner
cartridge that is indicated on the LCD before you get a
“Replace Drum” message.
Drum Error
Clean the corona wires. If the LCD still shows the same
error message after you have cleaned the corona wire,
replace the drum unit with a new one that is indicated on
the LCD.
Fuser Error
Turn off the power switch, wait a few seconds and then
turn it on again. Leave the machine for 15 minutes with
the power on.
Summary of Contents for DCP-9010CN
Page 11: ...Confidential CHAPTER 1 SPECIFICATIONS ...
Page 53: ...Confidential CHAPTER 2 THEORY OF OPERATION ...
Page 90: ...Confidential CHAPTER 3 ERROR INDICATION AND TROUBLESHOOTING ...
Page 201: ...Confidential CHAPTER 4 PERIODICAL MAINTENANCE ...
Page 224: ...Confidential CHAPTER 5 DISASSEMBLY AND ASSEMBLY ...
Page 440: ...Confidential CHAPTER 6 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...
Page 446: ...6 5 Confidential 10 Alert warning message appears click Continue Anyway to proceed ...
Page 456: ...Confidential CHAPTER 7 SERVICE FUNCTIONS ...
Page 464: ...7 6 Confidential For color scanning Fig 7 2 ...
Page 487: ...7 29 Confidential Cover page sample Fig 7 13 End page sample Fig 7 14 ...
Page 492: ...7 34 Confidential Color registration adjustment chart Fig 7 16 ...
Page 496: ...7 38 Confidential LED test pattern M68_L Fig 7 18 ...
Page 498: ...7 40 Confidential Fig 7 19 ...
Page 500: ...7 42 Confidential Color test pattern Fig 7 20 MCYK Y C K M YCMK_ _A ...
Page 518: ...Confidential CHAPTER 8 CIRCUIT DIAGRAMS WIRING DIAGRAM ...
Page 521: ...Confidential 8 2 High voltage Power Supply PCB Circuit Diagram SYS HITEK SPH 8N35 2 3 ...
Page 522: ...Confidential 8 3 High voltage Power Supply PCB Circuit Diagram SYS HITEK SPH 8N35 3 3 ...
Page 523: ...Confidential 8 4 High voltage Power Supply PCB Circuit Diagram MURATA MPH3316 1 3 ...
Page 524: ...Confidential 8 5 High voltage Power Supply PCB Circuit Diagram MURATA MPH3316 2 3 ...
Page 525: ...Confidential 8 6 High voltage Power Supply PCB Circuit Diagram MURATA MPH3316 3 3 ...
Page 526: ...Confidential 8 7 Low voltage Power Supply PCB Circuit Diagram 100V ...
Page 527: ...Confidential 8 8 Low voltage Power Supply PCB Circuit Diagram 200V ...
Page 528: ...Confidential 8 9 NCU PCB Circuit Diagram USA Canada ...
Page 529: ...Confidential 8 10 NCU PCB Circuit Diagram Europe Asia Oceania China ...
Page 530: ...Confidential 8 11 NCU PCB Circuit Diagram South Africa Gulf ...
Page 531: ...Confidential 8 12 2 WIRING DIAGRAM Wiring Diagram 1 2 ...
Page 532: ...Confidential 8 13 Wiring Diagram 2 2 ...
Page 590: ...Confidential APPENDIX 3 SERIAL NUMBERING SYSTEM ...
Page 592: ...App 3 2 Confidential Serial number of the LED ASSY Print position Fig App 3 4 Serial number ...
Page 593: ...Confidential APPENDIX 4 SCREW CATALOGUE ...
Page 595: ...Confidential APPENDIX 5 REFERENCES ...
Page 597: ...Confidential APPENDIX 6 GLOSSARY ...