7-1
Confidential
1.
MAINTENANCE MODE
The maintenance mode is exclusively designed for the checking, setting and adjustments of
the machine by using the buttons on the control panel cover ASSY. The EEPROM can be
customized according to the destination of the machine. Moreover, the operational check of
the LCD, operation panel board, and sensors, print test, display of the log information and
error codes, and change of the worker switches (WSW) can be performed.
1.1 How to Enter the Maintenance Mode
<Operating procedure>
(1) Press the
Menu
button and then the
Start/Black
button while the machine is in the ready
state. Next, press the
button four times to enter the maintenance mode.
(2) The machine beeps for one second and displays “
” on the LCD,
indicating that it is placed in the initial state of the maintenance mode, a mode in which the
machine is ready to accept entry from the buttons.
(3) To select any of the maintenance mode functions shown in the next page, enter the
maintenance mode that you want to use using the buttons.
1.2
How to Enter the End User-accessible Maintenance Mode
Basically, the maintenance-mode functions listed in the
should be accessed by
service personnel only. However, you can allow end users to access some of these under the
guidance of service personnel by phone, for example.
The end user-accessible functions are
shaded
in the table given on the
09, 10, 11, 12, 25, 43, 52, 53, 54, 68, 71, 72, 77, 80, 82, 87, 88
Function code 10 accesses the firmware switches, each of which has eight selectors. You
should not allow end users to access all of those selectors, but you can allow them to access
user-accessible selectors which are shaded in the firmware switch tables in
The service personnel should instruct end users to follow the procedure given below.
<Operating procedure>
(1) Press the
Menu
,
Start/Black
,
Menu
and
buttons in this order when the machine is in
the ready state. “MAINTENANCE 06” appears on the LCD.
(2) Press the
or
button to display the desired maintenance code on the LCD. Then
press the
OK
button.
To switch the machine back to the ready state, press the
Stop/Exit
button. When each of the
user-accessible functions is completed, the machine automatically returns to the ready state.
Memo:
FAX models equipped with numerical keypads can enter the maintenance mode in the
same way as conventional models; that is, by pressing the
Menu
,
*
,
2
,
8
,
6
and
4
buttons in this sequence.
Memo:
- To exit from the maintenance mode and switch to ready state, press the
9
button twice in
the initial state of the maintenance mode.
- When the
Stop/Exit
button is pressed, the machine beeps for one second and returns to
the initial state of the maintenance mode.
- When an incorrect maintenance mode is entered, the machine beeps for one second and
returns to the initial state of the maintenance mode.
Summary of Contents for DCP-9010CN
Page 11: ...Confidential CHAPTER 1 SPECIFICATIONS ...
Page 53: ...Confidential CHAPTER 2 THEORY OF OPERATION ...
Page 90: ...Confidential CHAPTER 3 ERROR INDICATION AND TROUBLESHOOTING ...
Page 201: ...Confidential CHAPTER 4 PERIODICAL MAINTENANCE ...
Page 224: ...Confidential CHAPTER 5 DISASSEMBLY AND ASSEMBLY ...
Page 440: ...Confidential CHAPTER 6 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...
Page 446: ...6 5 Confidential 10 Alert warning message appears click Continue Anyway to proceed ...
Page 456: ...Confidential CHAPTER 7 SERVICE FUNCTIONS ...
Page 464: ...7 6 Confidential For color scanning Fig 7 2 ...
Page 487: ...7 29 Confidential Cover page sample Fig 7 13 End page sample Fig 7 14 ...
Page 492: ...7 34 Confidential Color registration adjustment chart Fig 7 16 ...
Page 496: ...7 38 Confidential LED test pattern M68_L Fig 7 18 ...
Page 498: ...7 40 Confidential Fig 7 19 ...
Page 500: ...7 42 Confidential Color test pattern Fig 7 20 MCYK Y C K M YCMK_ _A ...
Page 518: ...Confidential CHAPTER 8 CIRCUIT DIAGRAMS WIRING DIAGRAM ...
Page 521: ...Confidential 8 2 High voltage Power Supply PCB Circuit Diagram SYS HITEK SPH 8N35 2 3 ...
Page 522: ...Confidential 8 3 High voltage Power Supply PCB Circuit Diagram SYS HITEK SPH 8N35 3 3 ...
Page 523: ...Confidential 8 4 High voltage Power Supply PCB Circuit Diagram MURATA MPH3316 1 3 ...
Page 524: ...Confidential 8 5 High voltage Power Supply PCB Circuit Diagram MURATA MPH3316 2 3 ...
Page 525: ...Confidential 8 6 High voltage Power Supply PCB Circuit Diagram MURATA MPH3316 3 3 ...
Page 526: ...Confidential 8 7 Low voltage Power Supply PCB Circuit Diagram 100V ...
Page 527: ...Confidential 8 8 Low voltage Power Supply PCB Circuit Diagram 200V ...
Page 528: ...Confidential 8 9 NCU PCB Circuit Diagram USA Canada ...
Page 529: ...Confidential 8 10 NCU PCB Circuit Diagram Europe Asia Oceania China ...
Page 530: ...Confidential 8 11 NCU PCB Circuit Diagram South Africa Gulf ...
Page 531: ...Confidential 8 12 2 WIRING DIAGRAM Wiring Diagram 1 2 ...
Page 532: ...Confidential 8 13 Wiring Diagram 2 2 ...
Page 590: ...Confidential APPENDIX 3 SERIAL NUMBERING SYSTEM ...
Page 592: ...App 3 2 Confidential Serial number of the LED ASSY Print position Fig App 3 4 Serial number ...
Page 593: ...Confidential APPENDIX 4 SCREW CATALOGUE ...
Page 595: ...Confidential APPENDIX 5 REFERENCES ...
Page 597: ...Confidential APPENDIX 6 GLOSSARY ...