2-79
Confidential
■
Error code D800
An error occurred during touch panel initialization.
<User Check>
- Check whether an object is placed on the touch panel.
■
Error code D900
An error occurred during panel PCB initialization.
<User Check>
- Check whether an object is placed on the control panel.
■
Error code DA00
After the initialization of the panel PCB, no response was sent from the panel PCB for a period
of time.
Touchscreen initialization failed
Remove any material which is on the touchscreen.
Step
Cause
Remedy
1
Touch panel ASSY harness
connection failure
Check the touch panel ASSY harness
connection and reconnect it.
2
Touch panel ASSY failure
Replace the touch panel ASSY.
3
Main PCB failure
Replace the main PCB ASSY.
-
Step
Cause
Remedy
1
Panel PCB harness connection
failure
Check the panel PCB harness connection
and reconnect it.
2
Panel PCB failure
Replace the panel cover ASSY.
3
Main PCB failure
Replace the main PCB ASSY.
-
Step
Cause
Remedy
1
Panel PCB failure
Replace the panel cover ASSY.
2
Main PCB failure
Replace the main PCB ASSY.
Summary of Contents for DCP-9020CDN
Page 47: ...2 8 Confidential 2 2 2 Scanning part Fig 2 4 ...
Page 89: ...2 50 Confidential Electrodes location of main body Fig 2 7 ...
Page 172: ...3 9 Confidential EM2 0 MOLYKOTE EM D110 2 0 mm dia ball EM2 0 Back cover ASSY Back cover ASSY ...
Page 345: ...5 7 Confidential Black and white scanning First side Front Fig 5 1 ...
Page 346: ...5 8 Confidential Black and white scanning Second side Back Fig 5 2 ...
Page 347: ...5 9 Confidential Color scanning First side Front Fig 5 3 ...
Page 348: ...5 10 Confidential Color scanning Second side Back Fig 5 4 ...
Page 384: ...5 46 Confidential LED test pattern M68_L Fig 5 17 ...
Page 429: ...App 3 8 Confidential When the following screen appears click Close to close the screen ...