Vertical streaks
Fig. 2-13
<User Check>
- Clean the corona wire of each drum unit for all four
colors.
- Return the cleaning tab of the corona wire to the
position.
- This symptom might stop occurring after making
several prints.
- Refer to the User’s guide and remove the dirt on the
exposure drum using a cotton swab.
- Replace the drum unit or toner cartridge with a new
one.
- Clean the LED ASSY.
- Open the joint cover ASSY and the back cover, and
leave them for 30 minutes or longer to draw moist air
and prevent condensation.
Step
Cause
Remedy
1
Dirt in the paper feed system
Wipe dirt off.
2
FG wires and FG plate
installation failure (Grounding
is not performed properly)
Retighten the screws that hold the FG wires
and FG plate.
Repair the bend of the tray ground spring of
the paper tray.
3
LED ASSY failure
Replace the LED ASSY.
4
Scratch and dirt on fuser unit
Replace the fuser unit.
Note:
If the machine continuously prints the same pattern including vertical streaks in particular,
black vertical streaks may appear on the paper since the electrostatic performance of the
exposure drum is decreased temporally.
Tray ground spring
Paper tray
<Bottom of paper tray>
Summary of Contents for DCP-9020CDN
Page 47: ...2 8 Confidential 2 2 2 Scanning part Fig 2 4 ...
Page 89: ...2 50 Confidential Electrodes location of main body Fig 2 7 ...
Page 172: ...3 9 Confidential EM2 0 MOLYKOTE EM D110 2 0 mm dia ball EM2 0 Back cover ASSY Back cover ASSY ...
Page 345: ...5 7 Confidential Black and white scanning First side Front Fig 5 1 ...
Page 346: ...5 8 Confidential Black and white scanning Second side Back Fig 5 2 ...
Page 347: ...5 9 Confidential Color scanning First side Front Fig 5 3 ...
Page 348: ...5 10 Confidential Color scanning Second side Back Fig 5 4 ...
Page 384: ...5 46 Confidential LED test pattern M68_L Fig 5 17 ...
Page 429: ...App 3 8 Confidential When the following screen appears click Close to close the screen ...