3-150
Confidential
8.66 High-voltage Power Supply PCB ASSY/HVPS Flat Cable
(1) Remove the Taptite cup S M3x8 SR screw and the Taptite pan (washer) B M4x12 DA
screw to remove the HVPS ground plate front from the Side frame R.
Fig. 3-217
(2) Remove the Taptite pan (washer) B M4x12 DA screw to remove the HVPS ground plate
rear from the Side frame R.
Fig. 3-218
Taptite cup S M3x8 SR
Side frame R
High-voltage power supply PCB ASSY
Taptite pan (washer)
B M4x12 DA
HVPS ground plate front
<Front side>
Taptite pan (washer) B M4x12 DA
Side frame R
High-voltage power supply PCB ASSY
HVPS ground plate rear
<Left side>