2-12
Confidential
3.
ERROR INDICATIONS
This machine includes a self-diagnosis function. If the machine does not work normally it
judges that an error has occurred, and indicates the corresponding error message on the LCD,
which in turn helps the service personnel to quickly find out the problem.
3.1 Error Codes
The shaded errors hardly occur under normal use. They may be caused by noise around the
installation site, variation in power supply voltage, or software failure.
Error
codes
Problem
Refer
to:
0100
ASIC error or motor driver error
occurred.
0201
Synchronization signal from the
main motor cannot be detected.
Or the main motor speed is
unstable after a set period of
time.
0202
Synchronization signal from the
process motor cannot be
detected. Or the process motor
speed is unstable after a set
period of time.
0203
---
0204
---
0205
---
0206
---
0207
---
0208
---
0209
---
0300
---
0401
---
0402
---
0501
The center thermistor of the
fuser unit does not reach the
specified temperature within the
specified time.
0502
The center thermistor of the
fuser unit does not reach the
specified temperature within the
specified time.
0503
The center thermistor of the
fuser unit detected a
temperature higher than the
specified value.
0504
After the center thermistor of the
fuser unit was normally heated, it
detected a temperature lower
than the specified value.
0505
The center thermistor of the
fuser unit detected a
temperature rise greater than the
specified value within a set
period of time.
0506
The center thermistor of the
fuser unit detected a
temperature fall greater than the
specified value within a set
period of time.
0507
---
0508
---
0509
---
050A
The center thermistor or side
thermistor of the fuser unit
detected some temperature error
in the hardware.
Error
codes
Problem
Refer
to:
Summary of Contents for DCP-9020CDN
Page 47: ...2 8 Confidential 2 2 2 Scanning part Fig 2 4 ...
Page 89: ...2 50 Confidential Electrodes location of main body Fig 2 7 ...
Page 172: ...3 9 Confidential EM2 0 MOLYKOTE EM D110 2 0 mm dia ball EM2 0 Back cover ASSY Back cover ASSY ...
Page 345: ...5 7 Confidential Black and white scanning First side Front Fig 5 1 ...
Page 346: ...5 8 Confidential Black and white scanning Second side Back Fig 5 2 ...
Page 347: ...5 9 Confidential Color scanning First side Front Fig 5 3 ...
Page 348: ...5 10 Confidential Color scanning Second side Back Fig 5 4 ...
Page 384: ...5 46 Confidential LED test pattern M68_L Fig 5 17 ...
Page 429: ...App 3 8 Confidential When the following screen appears click Close to close the screen ...