4-7
Confidential
2.
IF YOU REPLACE THE REGISTRATION
MARK L PCB ASSY AND REGISTRATION
MARK R PCB ASSY
■
What to do when replacing the registration mark L PCB ASSY and registration
mark R PCB ASSY
- Continuous Adjustments of Density and Registration Sensor (Function code 73)
2.1 Continuous Adjustments of Density and Registration
Sensor (Function code 73)
Perform continuous adjustments of density and registration sensor in accordance with
"1.4.28 Continuous adjustments of density and registration sensor" in Chapter 5
Memo:
Continuous adjustments of density and registration sensor (Function code 73)
,
Sensitivity adjustment of density sensor (Function code 72), Developing bias voltage
correction (Function code 83), and Adjustment of color registration (Adjustment of
inter-color position alignment) including registration sensor calibration (Function code 66)
are executed consecutively.