Confidential
App. 1-10
- Selectors 5 and 6: Busy tone detection in automatic sending mode
These selectors determine whether or not the machine automatically disconnects a line
upon detection of a busy tone in automatic sending mode.
Setting selector 6 to “0” ignores a busy tone so that the machine does not disconnect the
line. Setting selectors 5 and 6 to “0” and “1,” respectively, makes the machine detect a
busy tone only after dialing and disconnect the line.
Setting both of selectors 5 and 6 to “1” makes the machine detect a busy tone before and
after dialing and then disconnect the line.
- Selector 7: Busy tone detection in automatic receiving mode
This selector determines whether or not the machine automatically disconnects the line
upon detection of a busy tone in automatic receiving mode.
< WSW06 >
Selector No.
Function
Setting and Specifications
1
|
3
Redial/Pause
button setting
and 2nd dial tone detection
No. 1 2 3
0 0 0: No pause
0 0 1: 3.5 sec. wait
0 1 0: 7 sec. wait
0 1 1: 10.5 sec. wait
1 0 0: 2.8 sec. wait
1 0 1: 2nd dial tone detection
both in DP and push-
button (PB) dialing system
1 1 0: 2nd dial tone detection
only in pulse dialing (DP)
system
1 1 1: 2nd dial tone detection
both in DP and push-
button (PB) dialing system
4
|
6
Detection of international tone
No. 4 5 6
0 0 0: 50 ms
0 0 1: 250 ms
0 1 0: 500 ms
0 1 1: 620 ms
1 0 0: 800 ms
1 0 1: 1.5 sec.
1 1 0: 2.0 sec.
1 1 1: 2.5 sec.
7
No. of 2nd dial tone detection
cycles
0: 1 cycle
1: 2 cycles
8
Allowable instantaneous
interrupt during reception of 2nd
dial tone
0: 30 ms
1: 50 ms
Note:
Selectors 4 through 8 are not applicable in those countries where no dial tone detection is
supported, e.g., U.S.A.
Summary of Contents for DCP-9040CN
Page 309: ...Confidential 4 5 8 Alert warning message of WHQL appears Click Continue Anyway to proceed ...
Page 325: ...Confidential 5 6 Color scanning Fig 5 2 ...
Page 342: ...Confidential 5 23 Cover page sample Fig 5 13 End page sample Fig 5 14 ...
Page 365: ...Confidential 6 2 Charge High voltage Power Supply PCB Circuit Diagram 2 4 ...
Page 366: ...Confidential 6 3 Charge High voltage Power Supply PCB Circuit Diagram 3 4 ...
Page 367: ...Confidential 6 4 Charge High voltage Power Supply PCB Circuit Diagram 4 4 ...
Page 368: ...Confidential 6 5 Transfer High voltage Power Supply PCB Circuit Diagram 1 2 ...
Page 369: ...Confidential 6 6 Transfer High voltage Power Supply PCB Circuit Diagram 2 2 ...
Page 370: ...Confidential 6 7 Low voltage Power Supply PCB Circuit Diagram 100V ...
Page 371: ...Confidential 6 8 Low voltage Power Supply PCB Circuit Diagram 200V ...
Page 373: ...Confidential 6 10 Filter PCB Circuit Diagram ...