Confidential
App. 1-50
< WSW45 >
Selector No.
Function
Setting and Specifications
1
|
3
Delay time from when
documents are set until the
ADF starts drawing them in
No. 1 2 3
0 0 0: No automatic drawing-in
0 0 1: 1 sec.
0 1 0: 2 sec.
0 1 1: 3 sec.
1 0 0: 4 sec.
1 0 1: 5 sec.
1 1 0: 6 sec.
1 1 1: 7 sec.
4
|
6
Periodical correction intervals of
the reference voltage to be
applied to white level
compensation for document
scanning, during standby
No. 4 5 6
0 0 0: No correction of reference
voltage during standby
0 0 1: 10 sec.
0 1 0: 30 sec.
0 1 1: 1 min.
1 0 0: 3 min.
1 0 1: 5 min.
1 1 0: 10 min.
1 1 1: 30 min.
7
Standby position of the CIS unit
0: CIS home position
1: Location of the white-level reference
film
8
Line polarity reverse detection
function
0: No
1: Yes
Note:
WSW45 is applicable only to flat head-type models.
- Selectors 1 through 3: Delay time from when documents are set until the ADF starts
drawing them in
These selectors determine how long the ADF will delay automatic drawing-in of documents
(to the scanning standby position) after you set them in the ADF, as well as determining
whether or not the ADF automatically draws in documents.
- Selectors 4 through 6: Periodical correction intervals of the reference voltage applied to
white level compensation for document scanning, during standby
These selectors set the correction intervals (in seconds) of the reference voltage to be
applied to white level compensation for document scanning during standby, as well as
determining whether or not the controller makes the reference voltage correction during
standby. (Conventionally, the correction has been made immediately before the start of
actual scanning)
This function takes effect in copying. Making the correction during standby may shorten
the preparation time for copying.
Note:
Do not access these selectors.
Summary of Contents for DCP-9040CN
Page 309: ...Confidential 4 5 8 Alert warning message of WHQL appears Click Continue Anyway to proceed ...
Page 325: ...Confidential 5 6 Color scanning Fig 5 2 ...
Page 342: ...Confidential 5 23 Cover page sample Fig 5 13 End page sample Fig 5 14 ...
Page 365: ...Confidential 6 2 Charge High voltage Power Supply PCB Circuit Diagram 2 4 ...
Page 366: ...Confidential 6 3 Charge High voltage Power Supply PCB Circuit Diagram 3 4 ...
Page 367: ...Confidential 6 4 Charge High voltage Power Supply PCB Circuit Diagram 4 4 ...
Page 368: ...Confidential 6 5 Transfer High voltage Power Supply PCB Circuit Diagram 1 2 ...
Page 369: ...Confidential 6 6 Transfer High voltage Power Supply PCB Circuit Diagram 2 2 ...
Page 370: ...Confidential 6 7 Low voltage Power Supply PCB Circuit Diagram 100V ...
Page 371: ...Confidential 6 8 Low voltage Power Supply PCB Circuit Diagram 200V ...
Page 373: ...Confidential 6 10 Filter PCB Circuit Diagram ...