5-6
Confidential
1.3.3 Scanning lock (Function code: 06)
<Function>
This function is used to disable the scanning operation until the power is turned OFF and then
ON again.
<Operating Procedure>
(1) Press the [0] and [6] buttons in this order in the initial state of the maintenance mode.
"SCAN LOCKED" appears on the LCD, and scanning operation is disabled.
1.3.4 ADF performance test (Function code: 08)
<Function>
This function is used to test the performance of the automatic document feeder (ADF). The
machine counts the documents fed by the ADF and displays the result on the LCD.
<Operating Procedure>
(1) Load the documents. (Do not exceed the paper capacity of the ADF.) "DOC.READY"
appears on the LCD.
(2) Press the [0] and [8] buttons in this order.
(3) The documents are fed and ejected while the scanned pages are counted, displaying the
number of pages on the LCD as shown below.
(4) When the [Stop/Exit] button is pressed, the machine beeps for one second and returns
to the initial state of the maintenance mode.
ADF CHECK P.01
Current count (1st page in this example)
Summary of Contents for FAX-2950
Page 20: ...Confidential CHAPTER 1 SPECIFICATIONS ...
Page 35: ...Confidential CHAPTER 2 TROUBLESHOOTING ...
Page 45: ...2 8 Confidential 2 2 2 Scanning part Fig 2 4 ...
Page 122: ...Confidential CHAPTER 3 DISASSEMBLY REASSEMBLY ...
Page 130: ...3 6 Confidential 5 LUBRICATION There are no applicable parts for lubrication ...
Page 136: ...3 12 Confidential 3 New toner sensor PCB ASSY New toner sensor PCB ASSY Main PCB ASSY Guide ...
Page 204: ...Confidential CHAPTER 4 ADJUSTMENTS AND UPDATING SETTINGS AS REQUIRED AFTER PARTS REPLACEMENT ...
Page 217: ...Confidential CHAPTER 5 SERVICE FUNCTIONS ...
Page 224: ...5 5 Confidential Black and white color scanning Fig 5 1 ...
Page 263: ...Confidential CHAPTER 6 WIRING DIAGRAM ...
Page 266: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE ...
Page 267: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE CONTENTS 1 PERIODICAL REPLACEMENT PARTS 7 1 ...
Page 269: ...Confidential APPENDIX 1 SERIAL NUMBERING SYSTEM ...
Page 273: ...Confidential APPENDIX 3 INSTALLING MAINTENANCE DRIVER ...
Page 275: ...Confidential APPENDIX 4 HOW TO MAKE PROTECTIVE MATERIAL FOR DRUM UNIT ...